Thermodilution Cardiac Output MeasurementEffects of the Respiratory Cycle on Its Reproducibility
John H. Stevens;
Thomas A. Raffin, MD;
Frederick G. Mihm, MD;
Myer H. Rosenthal, MD;
Christian W. Stetz, MD
JAMA. 1985;253(15):2240-2242.
Abstract
Thermodilution cardiac output measurements are commonly employed in the management of critically ill patients. Serial measurements often show significant variation, and poor reproducibility limits their clinical utility. There are no clinical studies revealing when to perform thermodilution cardiac output measurements in relation to the respiratory cycle. We prospectively studied 32 patients in a randomized scheme comparing three thermodilution cardiac output measurements at peak-inspiration, at end-exhalation, or randomly in spontaneously breathing and mechanically ventilated patients. Saline injections initiated at peak-inspiration or end-exhalation resulted in cardiac output measurements with much smaller standard deviations than those seen with random injections. Thermodilution cardiac output measurements performed at random times in the respiratory cycle should be avoided, and we recommend initiating these measurements at end-exhalation.
(JAMA 1985;253:2240-2242)
Author Affiliations
From the Departments of Medicine (Mr Stevens and Drs Raffin and Stetz) and Anesthesiology (Drs Mihm and Rosenthal), Stanford University School of Medicine, Stanford, Calif.
Footnotes
Reprint requests to Assistant Chief of Medicine, Stanford University Medical Center, Stanford, CA 94305 (Dr Raffin).
CiteULike Connotea Del.icio.us Digg Reddit Technorati Twitter
What's this?
THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES
 |
Systemic arterial waveform analysis and assessment of blood flow during extracorporeal circulation
Romano et al.
Perfusion 2006;21:109-116.
ABSTRACT
Critical assessment of haemodynamic data
Wigfull and Cohen
Contin Educ Anaesth Crit Care Pain 2005;5:84-88.
ABSTRACT
| FULL TEXT
The Effects of Intraabdominally Insufflated Carbon Dioxide on Hepatic Blood Flow During Laparoscopic Surgery Assessed by Transesophageal Echocardiography
Meierhenrich et al.
Anesth. Analg. 2005;100:340-347.
ABSTRACT
| FULL TEXT
A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients
Jansen et al.
Br J Anaesth 2001;87:212-222.
ABSTRACT
| FULL TEXT
Effect of the mechanical ventilatory cycle on thermodilution right ventricular volumes and cardiac output
Groeneveld et al.
J. Appl. Physiol. 2000;89:89-96.
ABSTRACT
| FULL TEXT
Improved accuracy and precision of thermodilution cardiac output measurement using a dual thermistor catheter system
Lehmann and Platt
J Am Coll Cardiol 1999;33:883-891.
ABSTRACT
| FULL TEXT
Cardiac output in 1998
Singer
Heart 1998;79:425-428.
FULL TEXT
Cardiac Output by Thermodilution
McIntyre
JAMA 1985;254:2413-2413.
ABSTRACT
|