You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT JAMA
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 255 No. 6, February 14, 1986 TABLE OF CONTENTS
  JAMA
  •  Online Features
  ORIGINAL CONTRIBUTIONS
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (21)
 •Contact me when this article is cited
 Related Content
 •Similar articles in JAMA
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Is Serum Creatine Kinase-MB in Electrically Injured Patients Predictive of Myocardial Injury?

John W. McBride, MD; Kingsley R. Labrosse, PhD; Harry G. McCoy, PharmD; David H. Ahrenholz, MD; Lynn D. Solem, MD; Irvin F. Goldenberg, MD

JAMA. 1986;255(6):764-768.


Abstract

We undertook a retrospective study of 36 victims of high-voltage electrical contact injuries to determine the incidence and possible source of elevated creatine kinase (CK)-MB enzyme in their serum. Only two sustained myocardial infarctions (one late) according to history, electrocardiographic findings, and clinical course. Serum lactate dehydrogenase isoenzyme levels were abnormal but revealed no myocardial infarction patterns. Creatine kinase total activity, however, reached 1.5 to 1,140 times normal in 92% and the CK-MB level was abnormal in 50% despite the low incidence of myocardial damage. Skeletal muscle CK and CK-MB levels in four nonelectrically injured patients were comparable to those in normal muscle while CK and CK-MB activity was elevated in six such electrical injuries. There was a gradient in CK-MB activity with greatest CK-MB activity in "normal" muscle near the injury site, lesser amounts in border tissue, and least in the worst-injured site. We conclude that (1) myocardial injury is uncommon in high-voltage electrical injury and (2) skeletal muscle injured by high electrical voltage is stimulated to produce, as well as release, CK-MB.

(JAMA 1986;255:764-768)



Author Affiliations

From the Section of Cardiology (Drs McBride and Goldenberg), the Section of Clinical Chemistry, Department of Pathology (Dr Labrosse), the Departments of Clinical Pharmacology (Dr McCoy) and Surgery (Drs Ahrenholz and Solem), and the Burn Center (Drs Solem and Ahrenholz), the St Paul-Ramsey Medical Center; and the University of Minnesota Medical School, Minneapolis. Drs Labrosse and McCoy are currently with MEDTOX Laboratories, New Brighton, Minn.


Footnotes

Reprint requests to Section of Cardiology, St Paul-Ramsey Medical Center, 640 Jackson St, St Paul, MN 55101 (Dr McBride).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Narrative review: Electrocution and life-threatening electrical injuries.
Spies and Trohman
ANN INTERN MED 2006;145:531-537.
ABSTRACT | FULL TEXT  

A three year prospective audit of 212 presentations to the emergency department after electrical injury with a management protocol
Blackwell and Hayllar
Postgrad. Med. J. 2002;78:283-285.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1986 American Medical Association. All Rights Reserved.