You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT JAMA
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 268 No. 14, October 14, 1992 TABLE OF CONTENTS
  JAMA
  •  Online Features
  Topics in Radiology
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Contact me when this article is cited
 Related Content
 •Similar articles in JAMA
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati
What's this?

Factors Affecting Mammographic Visualization of the Breast After Augmentation Mammaplasty

Neal Handel, MD; Melvin J. Silverstein, MD; Parvis Gamagami, MD; J. Arthur Jensen, MD; Alan Collins, MS

JAMA. 1992;268(14):1913-1917.


Abstract

Objective.
—To measure the effect of various parameters on mammographic visualization of the breast after augmentation mammaplasty.

Design.
—Preoperative and postoperative mammography was performed in patients undergoing augmentation mammaplasty. The area of breast tissue visualized on each film was measured. Changes in the area visualized were correlated with a variety of different parameters.

Setting.
—The Breast Center, Van Nuys, Calif, a free-standing multidisciplinary breast diagnostic and treatment facility.

Patients.
—The 68 women (126 breasts) represent a consecutive sample of patients undergoing augmentation mammaplasty for whom preoperative and postoperative mammograms were available.

Main Outcome Measures.
—Area visualized was correlated with degree of capsular contracture, implant position, type of mammography, preoperative breast size, implant size, and implant type.

Results.
—The major factor affecting mammography is capsular contracture. Little or no capsular contracture results in a 30% reduction in the area visualized; moderate or severe contracture results in a 50% reduction. Other important factors include implant position (improved visualization with implant beneath pectoral muscle) and type of mammography performed (slightly more tissue seen with displacement technique). Very small preoperative breast size yields increased visualization. Implant size and type have little or no effect.

Conclusions.
—In most women with breast implants, there is a decrease in measurable breast tissue on the postaugmentation mammogram. Capsular contracture and implant position exert a profound effect; type of mammography performed and preoperative breast size are also significant.

(JAMA. 1992;268:1913-1917)



Author Affiliations

From The Breast Center, 14624 Sherman Way, Van Nuys, Calif.


Footnotes

Reprint requests to The Breast Center, 14624 Sherman Way, Van Nuys, CA 91405 (Dr Handel).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Effect of Breast Augmentation on the Accuracy of Mammography and Cancer Characteristics
Miglioretti et al.
JAMA 2004;291:442-450.
ABSTRACT | FULL TEXT  

Silicone Gel Breast Implants
Council on Scientific Affairs, American Medical As et al.
JAMA 1993;270:2602-2606.
ABSTRACT  

Radiology
Evens
JAMA 1993;270:259-260.
ABSTRACT  

Mammography After Augmentation Mammoplasty
Leibman
JAMA 1993;269:987-988.
ABSTRACT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1992 American Medical Association. All Rights Reserved.