You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT JAMA
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 270 No. 24, December 22, 1993 TABLE OF CONTENTS
  JAMA
  •  Online Features
  Brief Report
 This Article
 •References
 •Full text PDF
 •Correction
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citing articles on HighWire
 •Citing articles on Web of Science (15)
 •Contact me when this article is cited
 Related Content
 •Similar articles in JAMA
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Breath Alcohol Values Following Mouthwash Use

Jack G. Modell, MD; Jasmine P. Taylor, MD; Jeanette Y. Lee, PhD

JAMA. 1993;270(24):2955-2956.


Abstract

Objective.
—To determine whether breath alcohol values (BrAV) attained following mouthwash use pose a realistic threat to the accuracy of blood alcohol determinations by breath analysis.

Design.
—Nonrandomized, open-label trial.

Setting.
—Outpatient research office.

Participants.
—Ten normal subjects; convenience sample.

Interventions.
—Breath alcohol measurements were made 2, 4, 6, 10, and 15 minutes following rinsing of the mouth with Listerine (29.6% alcohol), Scope (18.9% alcohol), and Lavoris (6.0% alcohol) using the Alco-Sensor III intoximeter.

Main Outcome Measures.
—Breath alcohol values over time.

Results.
—Breath alcohol values following mouthwash use decayed exponentially (r2≥.98, P<.001) from mean values 2 minutes following mouthwash use of 52.8 mmol/L (240 mg/dL) for Listerine, 37.4 mmol/L (170 mg/dL) for Scope, and 7.9 mmol/L (36 mg/dL) for Lavoris to mean and maximum values after 10 minutes that were well below the usual driving-while-intoxicated range (≥17.6 mmol/L [80 mg/ dL]) for all three brands. The nonalcoholic mouthwash ingredients did not significantly affect the BrAVs attained.

Conclusion.
—The decay of BrAVs following mouthwash use is sufficiently rapid that mouthwash use would not pose a realistic threat to the accuracy of blood alcohol determinations by breath analysis under normal circumstances. Use of mouthwash immediately prior to breath testing, as might occur in the car or workplace in a mistaken attempt to hide the smell of alcohol or other substances, may, however, significantly increase the measured BrAV.

(JAMA. 1993;270:2955-2956)



Author Affiliations

From the Department of Psychiatry (Drs Modell and Taylor) and the Biostatistics Unit, Comprehensive Cancer Center (Dr Lee), University of Alabama School of Medicine, Birmingham.


Footnotes

Reprint requests to Department of Psychiatry, University of Alabama School of Medicine, 1700 Seventh Ave S, No. 209, Birmingham, AL 35294-0018 (Dr Modell).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Breath Alcohol After Using Mouthwash
Brown
JAMA 1994;271:1400-1401.
ABSTRACT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1993 American Medical Association. All Rights Reserved.