You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT JAMA
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 270 No. 3, July 21, 1993 TABLE OF CONTENTS
  JAMA
  •  Online Features
  Original Contributions
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (85)
 •Contact me when this article is cited
 Related Content
 •Similar articles in JAMA
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Examination Gloves as Barriers to Hand Contamination in Clinical Practice

Robin J. Olsen, RN, CIC; Patricia Lynch, RN, MBA, CIC; Marie B. Coyle, PhD; Jeanne Cummings, RN, CIC; Teresa Bokete, MS; Walter E. Stamm, MD

JAMA. 1993;270(3):350-353.


Abstract

Objective.
—To test the effectiveness of vinyl and latex gloves as barriers to hand contamination with gram-negative organisms and enterococci during routine hospital procedures.

Design and Interventions.
—We studied 137 procedures during which a health care worker's gloved hand contacted a patient's mucous membrane and was thus potentially contaminated with gram-negative rods or enterococci. Quantitative hand cultures were obtained from each health care worker before and after the gloved contact using a modified glove juice method, and the exterior glove surface was also quantitatively cultured after patient contact. Used gloves were then tested for leaks using the American Society for Testing and Materials' watertight test.

Setting.
—Harborview Medical Center, a 330-bed city-county hospital and level I regional trauma and burn center, is both a teaching facility affiliated with the University of Washington and the major provider of care to indigent and uninsured persons in Seattle—King County, Washington.

Patients and Other Participatns.
—Respiratory therapists performing endotracheal tube care on intubated intensive care unit patients, registered nurses performing digital rectal stimulation for bowel training on patients with spinal cord injury in the rehabilitation ward, and dentists performing routine dental examinations and procedures on healthy outpatients in the dental clinic.

Main Outcome Measure and Results.
—Eighty-six of the 135 gloves cultured had gram-negative rods or enterococci on the external surface after use and were thus sources of potential hand contamination. Microbial contamination of the health care worker's hands occurred in 11 (13%; 95% confidence interval, 6% to 20%) of these 86 events, and was more frequent with vinyl (10 of 42) than latex (one of 44) gloves (P<.01). After use, glove leaks were also more frequent in vinyl gloves (26 of 61) than with latex gloves (six of 70) (P<.001). Even when leaks were present, gloves prevented hand contamination in 77% of instances and quantitative counts of microorganisms contaminating hands were 2 to 4 logs less than counts on external glove surfaces. Health care workers reported awareness of the presence of glove leaks in only seven (22%) of the 32 events in which leaks were subsequently demonstrated.

Conclusions.
—Under conditions of routine use, gloves effectively function as a protective barrier even when leaks are present. Latex gloves were less frequently associated with leaks and hand contamination. Since hand contamination occurred after 13% of exposures and cannot be readily identified by health care workers, routine hand washing should be done after each patient contact.

(JAMA. 1993;270:350-353)



Author Affiliations

From the Departments of Epidemiology (Mss Olsen, Lynch, and Cummings), Clinical Microbiology (Dr Coyle), Medicine (Dr Stamm), and Infectious Disease (Dr Stamm), Harborview Medical Center, Seattle, Wash; and the National Health Institute, Gaborone, Botswana (Ms Bokete).


Footnotes

Reprint requests to Hospital Epidemiology, Harborview Medical Center, 325 Ninth Ave, Seattle, WA 98104 (Ms Olsen).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Effectiveness of Gloves and Infection Control in Dentistry: Student and Provider Perspectives
Kanjirath et al.
J Dent Educ 2009;73:571-580.
ABSTRACT | FULL TEXT  

Infection Prevention and Control in Pediatric Ambulatory Settings
Committee on Infectious Diseases
Pediatrics 2007;120:650-665.
ABSTRACT | FULL TEXT  

The Use of Latex Gloves in the School Setting
Purcell
The Journal of School Nursing 2006;22:207-211.
ABSTRACT | FULL TEXT  

Hand Hygiene: A Frequently Missed Lifesaving Opportunity During Patient Care
Trampuz and Widmer
Mayo Clin Proc. 2004;79:109-116.
ABSTRACT  

Latex Allergy: An Update
Hepner and Castells
Anesth. Analg. 2003;96:1219-1229.
FULL TEXT  

Infection Control in the ICU
Eggimann and Pittet
Chest 2001;120:2059-2093.
ABSTRACT | FULL TEXT  

The health professional's role in preventing nosocomial infections
Saloojee and Steenhoff
Postgrad. Med. J. 2001;77:16-19.
ABSTRACT | FULL TEXT  

A comparison of soap, alcohol and glove use during the nappy-changing procedure in a special care baby unit
Chuadleigh and Buckingham
Journal of Research in Nursing 2000;5:437-449.
ABSTRACT  

Relationships between Enterococcal Virulence and Antimicrobial Resistance
Mundy et al.
Clin. Microbiol. Rev. 2000;13:513-522.
ABSTRACT | FULL TEXT  

Glove Leakage Rates as a Function of Latex Content and Brand: Caveat Emptor
Muto et al.
Arch Surg 2000;135:982-985.
ABSTRACT | FULL TEXT  

Infection Control in Physicians' Offices
Committee on Infectious Diseases and Committee on
Pediatrics 2000;105:1361-1369.
ABSTRACT | FULL TEXT  

Issues in Clinical Nursing Research: You + Research = Nursing Practice Program
Robinson
West J Nurs Res 1997;19:265-269.
 

Transmission of Hepatitis B Virus to Multiple Patients from a Surgeon without Evidence of Inadequate Infection Control
Harpaz et al.
NEJM 1996;334:549-554.
ABSTRACT | FULL TEXT  

Are Gloves Effective Protective Barriers in Clinical Practice?
Journal Watch Dermatology 1993;1993:1-1.
FULL TEXT  

ARE GLOVES EFFECTIVE BARRIERS TO INFECTION?
JWatch General 1993;1993:2-2.
FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1993 American Medical Association. All Rights Reserved.