Examination Gloves as Barriers to Hand Contamination in Clinical Practice
Robin J. Olsen, RN, CIC;
Patricia Lynch, RN, MBA, CIC;
Marie B. Coyle, PhD;
Jeanne Cummings, RN, CIC;
Teresa Bokete, MS;
Walter E. Stamm, MD
JAMA. 1993;270(3):350-353.
Abstract
 |  |
Objective. —To test the effectiveness of vinyl and latex gloves as barriers to hand contamination with gram-negative organisms and enterococci during routine hospital procedures.
Design and Interventions. —We studied 137 procedures during which a health care worker's gloved hand contacted a patient's mucous membrane and was thus potentially contaminated with gram-negative rods or enterococci. Quantitative hand cultures were obtained from each health care worker before and after the gloved contact using a modified glove juice method, and the exterior glove surface was also quantitatively cultured after patient contact. Used gloves were then tested for leaks using the American Society for Testing and Materials' watertight test.
Setting. —Harborview Medical Center, a 330-bed city-county hospital and level I regional trauma and burn center, is both a teaching facility affiliated with the University of Washington and the major provider of care to indigent and uninsured persons in Seattle—King County, Washington.
Patients and Other Participatns. —Respiratory therapists performing endotracheal tube care on intubated intensive care unit patients, registered nurses performing digital rectal stimulation for bowel training on patients with spinal cord injury in the rehabilitation ward, and dentists performing routine dental examinations and procedures on healthy outpatients in the dental clinic.
Main Outcome Measure and Results. —Eighty-six of the 135 gloves cultured had gram-negative rods or enterococci on the external surface after use and were thus sources of potential hand contamination. Microbial contamination of the health care worker's hands occurred in 11 (13%; 95% confidence interval, 6% to 20%) of these 86 events, and was more frequent with vinyl (10 of 42) than latex (one of 44) gloves (P<.01). After use, glove leaks were also more frequent in vinyl gloves (26 of 61) than with latex gloves (six of 70) (P<.001). Even when leaks were present, gloves prevented hand contamination in 77% of instances and quantitative counts of microorganisms contaminating hands were 2 to 4 logs less than counts on external glove surfaces. Health care workers reported awareness of the presence of glove leaks in only seven (22%) of the 32 events in which leaks were subsequently demonstrated.
Conclusions. —Under conditions of routine use, gloves effectively function as a protective barrier even when leaks are present. Latex gloves were less frequently associated with leaks and hand contamination. Since hand contamination occurred after 13% of exposures and cannot be readily identified by health care workers, routine hand washing should be done after each patient contact.
(JAMA. 1993;270:350-353)
Author Affiliations
From the Departments of Epidemiology (Mss Olsen, Lynch, and Cummings), Clinical Microbiology (Dr Coyle), Medicine (Dr Stamm), and Infectious Disease (Dr Stamm), Harborview Medical Center, Seattle, Wash; and the National Health Institute, Gaborone, Botswana (Ms Bokete).
Footnotes
Reprint requests to Hospital Epidemiology, Harborview Medical Center, 325 Ninth Ave, Seattle, WA 98104 (Ms Olsen).
CiteULike Connotea Del.icio.us Digg Reddit Technorati Twitter
What's this?
THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES
 |
Effectiveness of Gloves and Infection Control in Dentistry: Student and Provider Perspectives
Kanjirath et al.
J Dent Educ 2009;73:571-580.
ABSTRACT
| FULL TEXT
Infection Prevention and Control in Pediatric Ambulatory Settings
Committee on Infectious Diseases
Pediatrics 2007;120:650-665.
ABSTRACT
| FULL TEXT
The Use of Latex Gloves in the School Setting
Purcell
The Journal of School Nursing 2006;22:207-211.
ABSTRACT
| FULL TEXT
Hand Hygiene: A Frequently Missed Lifesaving Opportunity During Patient Care
Trampuz and Widmer
Mayo Clin Proc. 2004;79:109-116.
ABSTRACT
Latex Allergy: An Update
Hepner and Castells
Anesth. Analg. 2003;96:1219-1229.
FULL TEXT
Infection Control in the ICU
Eggimann and Pittet
Chest 2001;120:2059-2093.
ABSTRACT
| FULL TEXT
The health professional's role in preventing nosocomial infections
Saloojee and Steenhoff
Postgrad. Med. J. 2001;77:16-19.
ABSTRACT
| FULL TEXT
A comparison of soap, alcohol and glove use during the nappy-changing procedure in a special care baby unit
Chuadleigh and Buckingham
Journal of Research in Nursing 2000;5:437-449.
ABSTRACT
Relationships between Enterococcal Virulence and Antimicrobial Resistance
Mundy et al.
Clin. Microbiol. Rev. 2000;13:513-522.
ABSTRACT
| FULL TEXT
Glove Leakage Rates as a Function of Latex Content and Brand: Caveat Emptor
Muto et al.
Arch Surg 2000;135:982-985.
ABSTRACT
| FULL TEXT
Infection Control in Physicians' Offices
Committee on Infectious Diseases and Committee on
Pediatrics 2000;105:1361-1369.
ABSTRACT
| FULL TEXT
Issues in Clinical Nursing Research: You + Research = Nursing Practice Program
Robinson
West J Nurs Res 1997;19:265-269.
Transmission of Hepatitis B Virus to Multiple Patients from a Surgeon without Evidence of Inadequate Infection Control
Harpaz et al.
NEJM 1996;334:549-554.
ABSTRACT
| FULL TEXT
Are Gloves Effective Protective Barriers in Clinical Practice?
Journal Watch Dermatology 1993;1993:1-1.
FULL TEXT
ARE GLOVES EFFECTIVE BARRIERS TO INFECTION?
JWatch General 1993;1993:2-2.
FULL TEXT
|