You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT JAMA
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 285 No. 9, March 7, 2001 TABLE OF CONTENTS
  JAMA
  •  Online Features
  Clinical Cardiology
 This Article
 •Full text
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on ISI (76)
 •Contact me when this article is cited
 Related Content
 •Related letter
 •Related articles
 •Similar articles in JAMA
 Topic Collections
 •Cardiovascular Intervention
 •Pacemakers/ Defibrillators
 •Alert me on articles by topic

Improving Survival From Sudden Cardiac Arrest

The Role of the Automated External Defibrillator

John P. Marenco, MD; Paul J. Wang, MD; Mark S. Link, MD; Munther K. Homoud, MD; N. A. Mark Estes III, MD

JAMA. 2001;285:1193-1200.

Context  Sudden cardiac death is a major public health problem in the United States, and improving survival after out-of-hospital cardiac arrest has been the subject of intense study. Early defibrillation has been shown to be critical to improving survival. Use of automated external defibrillators (AEDs) has become an important component of emergency medical systems, and recent advances in AED technology have allowed expansion of AED use to nontraditional first responders and the lay public.

Objectives  To examine advancements in AED technology, review the impact of AEDs on time to defibrillation and survival, and explore the future role of AEDs in the effort to improve survival following sudden cardiac arrest.

Data Sources  MEDLINE was searched for articles from 1966 through December 2000 (Medical Subject Headings: electric countershock, heart arrest, resuscitation, emergency medical services; keywords: automatic external defibrillator, automated external defibrillator, public access defibrillation). Reference lists of relevant articles, news releases, and product information from manufacturers were also reviewed.

Study Selection  Initial MEDLINE search produced 4816 articles, from which 101 articles were selected for referencing based on having been published in a peer-reviewed journal and on relevance to the subject of the manuscript as determined by all 5 authors.

Data Extraction  All studies were critically reviewed for relevance, accuracy, and quality of data and study design by all authors.

Data Synthesis  Recent advances in AED technology and design have resulted in marked simplification of AED operation, improvements in accuracy and effectiveness, and reductions in cost. Use of AEDs by first responders and laypersons has reduced time to defibrillation and improved survival from sudden cardiac arrest in several communities. Initial studies of the cost-effectiveness of AED use in comparison with other commonly used treatments are favorable.

Conclusion  The AED represents an efficient method of delivering defibrillation to persons experiencing out-of-hospital cardiac arrest and its use by both traditional and nontraditional first responders appears to be safe and effective. The rapidly expanding role of AEDs in traditional emergency medical systems is supported by the literature, and initial studies of public access to defibrillation offer hope that further improvements in survival after sudden cardiac death can be achieved.


Author Affiliations: New England Cardiac Arrhythmia Center, Division of Cardiology, Department of Medicine, New England Medical Center, Boston, Mass.


RELATED LETTER

Informed Consent for Public Automated External Defibrillation
Anne Scheetz
JAMA. 2001;286(1):47.
EXTRACT | FULL TEXT  

RELATED ARTICLES

March 7, 2001
JAMA. 2001;285(9):1229-1230.
EXTRACT | FULL TEXT  

Heart Emergencies Caused by Irregular Heartbeat
JAMA. 2001;285(9):1248.
PDF  


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Can Home AEDs Improve Survival?
Callans
NEJM 2008;358:1853-1855.
FULL TEXT  

Prediction and Prevention of Sudden Cardiac Arrest: Lessons Learned in Schools
Estes
Circulation 2007;116:1341-1343.
FULL TEXT  

ACC/AHA/ESC 2006 Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death--Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death)
Developed in Collaboration With the European Heart et al.
J Am Coll Cardiol 2006;48:1064-1108.
FULL TEXT  

ACC/AHA/ESC 2006 Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: A Report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death)
Developed in Collaboration With the European Heart et al.
J Am Coll Cardiol 2006;48:e247-e346.
FULL TEXT  

ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death--executive summary: A report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop Guidelines for Management of Patients with Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society.
Zipes et al.
Eur Heart J 2006;27:2099-2140.
FULL TEXT  

ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: A report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society
Writing Committee Members et al.
Europace 2006;8:746-837.
FULL TEXT  

Recalls and safety alerts affecting automated external defibrillators.
Shah and Maisel
JAMA 2006;296:655-660.
ABSTRACT | FULL TEXT  

Automated external defibrillators--device reliability and clinical benefits.
Estes
JAMA 2006;296:700-702.
FULL TEXT  

The Automated External Defibrillator: Clinical Benefits and Legal Liability
England et al.
JAMA 2006;295:687-690.
FULL TEXT  

A 2-Tiered Approach to In-Hospital Defibrillation: Nurses Respond to a Trial of Using Automated External Defibrillators as Part of a Code-Team Protocol
Kyller and Johnstone
Crit Care Nurse 2005;25:25-33.
FULL TEXT  

Task Force 10: Automated external defibrillators
Myerburg et al.
J Am Coll Cardiol 2005;45:1369-1371.
FULL TEXT  

Automatic external defibrillation in a 6 year old
Konig et al.
Arch. Dis. Child. 2005;90:310-311.
ABSTRACT | FULL TEXT  

A program encouraging early defibrillation results in improved in-hospital resuscitation efficacy
Zafari et al.
J Am Coll Cardiol 2004;44:846-852.
ABSTRACT | FULL TEXT  

Temporal Trends in Coronary Heart Disease Mortality and Sudden Cardiac Death From 1950 to 1999: The Framingham Heart Study
Fox et al.
Circulation 2004;110:522-527.
ABSTRACT | FULL TEXT  

Defibrillators
Journal of the American Dental Association 2004;135:366-367.
FULL TEXT  

Cardiac Arrest Outside of a Hospital: How Can We Improve Results of Resuscitation?
Wellens et al.
Circulation 2003;107:1948-1950.
FULL TEXT  

Impact of Community-Wide Police Car Deployment of Automated External Defibrillators on Survival From Out-of-Hospital Cardiac Arrest
Myerburg et al.
Circulation 2002;106:1058-1064.
ABSTRACT | FULL TEXT  

The PULSE Initiative: Scientific Priorities and Strategic Planning for Resuscitation Research and Life Saving Therapies
Becker et al.
Circulation 2002;105:2562-2570.
FULL TEXT  

Automated External Defibrillators in Health/Fitness Facilities: Supplement to the AHA/ACSM Recommendations for Cardiovascular Screening, Staffing, and Emergency Policies at Health/Fitness Facilities
Balady et al.
Circulation 2002;105:1147-1150.
FULL TEXT  

Bringing order from chaos: The challenge of training lay responders to use automated external defibrillators and provide cardiopulmonary resuscitation
Woollard
Health Education Journal 2002;61:197-211.
ABSTRACT  

Implantable Cardioverter Defibrillator: A Volkswagon or a Rolls Royce: How Much Will You Pay to Save a Life?
Hallstrom and Zipes
Circulation 2001;104 :e148-e148.
FULL TEXT  

Saving Time Saves Lives
Zipes
Circulation 2001;104:2506-2508.
FULL TEXT  

Cost-effectiveness of Automated External Defibrillators on Airlines
Groeneveld et al.
JAMA 2001;286:1482-1489.
ABSTRACT | FULL TEXT  

Primary Prevention of Sudden Death With Implantable Defibrillator Therapy in Patients With Cardiac Disease: Can We Afford to Do It? (Can We Afford Not To?)
Exner et al.
Circulation 2001;104:1564-1570.
FULL TEXT  

Informed Consent for Public Automated External Defibrillation
Scheetz
JAMA 2001;286:47-47.
FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2001 American Medical Association. All Rights Reserved.