You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT JAMA
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 301 No. 22, June 10, 2009 TABLE OF CONTENTS
  JAMA
  •  Online Features
  Letters
 This Article
 •Full text
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Contact me when this article is cited
 Related Content
 •Related article
 •Related letters
 •Similar articles in JAMA
 Topic Collections
 •Cardiovascular System
 •Quality of Care
 •Patient Safety/ Medical Error
 •Radiation Therapy
 •Radiologic Imaging
 •Diagnosis
 •Angiology
 •Computed Tomography
 •Cardiovascular Disease/ Myocardial Infarction
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Radiation Doses Associated With Cardiac Computed Tomography Angiography

Since this article does not have an abstract, we have provided the first 150 words of the full text and any section headings.

To the Editor: Dr Hausleiter and colleagues1 compared radiation doses resulting from different CCTA studies and concluded that identification of factors that influence radiation dose may be important. While technical characteristics clearly influence the radiation dose, major differences in radiation dose could also arise from the calculation methodology. For example, the authors calculated the effective dose using a region-specific factor of 0.014, whereas a study by Husmann et al2 used a conversion factor of 0.017. Using different methods for calculating the effective dose can be misleading. The flaw in the concept of effective dose calculation is mainly due to the disparity of the tissue-weighting factors, which stand at the foundation of effective dose calculation.3-5 To eliminate this discrepancy, DLP values rather than effective dose for different CT scenarios should be compared, because DLP calculation is standardized and it is currently displayed by a majority of the CT scanners. Moreover, the . . . [Full Text of this Article]

Razvan C. Opreanu, MD; John P. Kepros, MD, MBA
john.kepros@hc.msu.edu
Department of Surgery
Michigan State University
East Lansing



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

RELATED ARTICLE

Estimated Radiation Dose Associated With Cardiac CT Angiography
Jörg Hausleiter, Tanja Meyer, Franziska Hermann, Martin Hadamitzky, Markus Krebs, Thomas C. Gerber, Cynthia McCollough, Stefan Martinoff, Adnan Kastrati, Albert Schömig, and Stephan Achenbach
JAMA. 2009;301(5):500-507.
ABSTRACT | FULL TEXT  

RELATED LETTERS

Radiation Doses Associated With Cardiac Computed Tomography Angiography
Joseph M. Price
JAMA. 2009;301(22):2324.
EXTRACT | FULL TEXT  

Radiation Doses Associated With Cardiac Computed Tomography Angiography
Iyad N. Daher
JAMA. 2009;301(22):2324.
EXTRACT | FULL TEXT  

Radiation Doses Associated With Cardiac Computed Tomography Angiography—Reply
Jörg Hausleiter, Thomas C. Gerber, and Stephan Achenbach
JAMA. 2009;301(22):2325.
EXTRACT | FULL TEXT  






HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2009 American Medical Association. All Rights Reserved.