 |
 |

Exercise Echocardiography or Exercise SPECT Imaging?
A Meta-analysis of Diagnostic Test Performance
Kirsten E. Fleischmann, MD, MPH;
Maria G. M. Hunink, MD, PhD;
Karen M. Kuntz, ScD;
Pamela S. Douglas, MD
JAMA. 1998;280:913-920.
ABSTRACT
 |  |
Context. Cardiac imaging has advanced rapidly, providing clinicians with several choices for evaluating patients with suspected coronary artery disease, but few studies compare modalities directly.
Objectives. To review the contemporary literature and to compare the diagnostic performance of exercise echocardiography (ECHO) and exercise single-photon emission computed tomography (SPECT) imaging in the diagnosis of coronary artery disease.
Data Sources. Studies published between January 1990 and October 1997 identified from MEDLINE search; bibliographies of reviews and original articles; and suggestions from experts in each area.
Study Selection. Articles were included if they discussed exercise ECHO and/or exercise SPECT imaging with thallous chloride TI 201 (thallium) or technetium Tc 99m sestamibi for detection and/or evaluation of coronary artery disease, if data on coronary angiography were presented as the reference test, and if the absolute numbers of true-positive, false-negative, true-negative, and false-positive observations were available or derivable from the data presented. Studies performed exclusively in patients after myocardial infarction, after percutaneous transluminal coronary angioplasty, after coronary artery bypass grafting, or with recent unstable coronary syndromes were excluded.
Data Extraction. Clinical variables, technical factors, and test performance were independently extracted by 2 reviewers on a standardized spreadsheet. Discrepancies were resolved by consensus.
Results. Forty-four articles met inclusion criteria. In pooled data weighted by the sample size of each study, exercise ECHO had a sensitivity of 85% (95% confidence interval [CI], 83%-87%) with a specificity of 77% (95% CI, 74%-80%). Exercise SPECT yielded a similar sensitivity of 87% (95% CI, 86%-88%) but a lower specificity of 64% (95% CI, 60%-68%). In a summary receiver operating characteristic model comparing exercise ECHO performance to exercise SPECT, exercise ECHO was associated with significantly better discriminatory power (parameter estimate, 1.18; 95% CI, 0.71-1.65), when adjusted for age, publication year, and a setting including known coronary artery disease for SPECT studies. In models comparing the discriminatory abilities of exercise ECHO and exercise SPECT vs exercise testing without imaging, both ECHO and SPECT performed significantly better than exercise testing. The incremental improvement in performance was greater for ECHO (3.43; 95% CI, 2.74-4.11) than for SPECT (1.49; 95% CI, 0.91-2.08).
Conclusions. Exercise ECHO and exercise SPECT have similar sensitivities for the detection of coronary artery disease, but exercise ECHO has better specificity and, therefore, higher overall discriminatory capabilities as used in contemporary practice.
INTRODUCTION
CORONARY ARTERY disease is the leading cause of death in men and women in the United States.1 Methods of detecting and assessing the presence and extent of disease have become increasingly important in applying therapies to decrease morbidity and mortality.2 Exercise electrocardiography (ECG) is widely used for noninvasive detection of coronary artery disease due to its ready availability and relatively low cost, but imaging techniques such as myocardial perfusion scintigraphy or echocardiography (ECHO) are often added to improve detection and/or localization of exercise-induced ischemia or in patients in whom the ECG is uninterpretable.
The choice between these 2 imaging modalities should rest in large part with a comparison of their diagnostic accuracy based on an aggregate of the available experience. Limited data are available comparing the performance of exercise single-photon emission computed tomography (SPECT) imaging and exercise ECHO directly,3-8 in that studies evaluated modest numbers of patients or were conducted by physicians and centers more expert in one technique than the other. Interpretation of the literature overall has been hampered by significant variability in case mix and pretest probability of disease, differences in the positivity criteria used, and the lack of reliable techniques to combine reports on the performance of diagnostic tests.9 Therefore, we undertook a meta-analysis of the contemporary literature on exercise SPECT imaging and exercise ECHO using a new methodologic tool, summary receiver operating characteristic (SROC) analysis.10-12
METHODS
Data Extraction
A literature review was performed to identify articles published from January 1990 to October 1997 in the English-language literature on exercise SPECT imaging and exercise ECHO.12 We focused on this period because both exercise ECHO and exercise SPECT were in widespread clinical use. Also, these years postdated several potentially important developments in myocardial perfusion imaging, such as SPECT techniques and the introduction of technetium Tc 99m sestamibi as an imaging agent. Articles were obtained through a MEDLINE search using the key words coronary disease and exercise test in conjunction with either echocardiography, thallium or thallium radioisotopes, or sestamibi and restricted by the term human; from bibliographies of original and review articles; and in response to suggestions by experts in each area.
Articles3-8,14-51 were included in the analysis if (1) exercise ECHO and/or exercise SPECT imaging were performed with thallous chloride Tl 201 (thallium) or technetium Tc 99m sestamibi to detect and/or evaluate coronary artery disease (if data on exercise ECG results in the same patient population were also presented, these data were extracted, although a comprehensive search of the literature concerning standard exercise testing was not performed); (2) data on coronary angiography were presented as the reference test; and (3) the absolute numbers of true-positive, false-negative, true-negative, and false-positive observations were available or derivable from the data presented. Studies performed exclusively in patients after myocardial infarction (MI), after percutaneous transluminal coronary angioplasty, after coronary artery bypass grafting (CABG), or with unstable coronary syndromes were excluded. One stress ECHO article was excluded because of its substantially different positivity criterion,13 namely displacement of the atrioventricular plane. In cases in which authors had published several reports in quick succession, we were able to contact them and to determine whether multiple analyses were reported on a substantially overlapping patient population. If this was the case, only 1 report was used in the analysis to avoid undue influence by results in one cohort of patients. A radiologist (M.G.M.H.) and cardiologist (K.E.F.) independently extracted data on clinical variables, technical factors, and test performance by means of a standardized spreadsheet. Discrepancies were resolved by consensus. Variables extracted included identifying information (first author, journal, city, and institution), publication year, mean age, percentage of male patients, clinical indication or setting and percentage of patients with previous MI, percutaneous transluminal coronary angioplasty, or CABG surgery. In addition, we recorded such test factors as the test used, the type of exercise performed, type of radionuclide used (if applicable), the positivity criterion used, the reference test used, how authors defined significant coronary artery disease (eg, 50% stenosis or 70% stenosis), and the presence of possible verification bias. The number of patients with and without disease, number of true positives and false positives, and percentage of diagnostic tests (patients reached at least 85% of their predicted maximal heart rate) were extracted as well as the percentage of uninterpretable tests and morbidity and mortality associated with each test, if provided.
If the article reported sensitivity and specificity data for important patient subsets, such as patients with multivessel disease, these data were extracted separately. If several types of tests were assessed in the same report (ie, exercise ECG, exercise ECHO, and exercise SPECT), data on test performance were extracted for each. An assessment of the likelihood of verification bias52 was made by noting whether the decision to proceed to the reference test, in this case contrast angiography, was in part dependent on the results of the noninvasive test. Since positive noninvasive test results are more likely to be followed up by an invasive test, this tends to increase the chance of detecting a true positive relative to a false negative and tends to increase the chance of detecting a false positive relative to a true negative. Therefore, sensitivity may appear falsely elevated and specificity falsely depressed in the verified sample.
Weighted Pooled Analysis
In our analysis, pooled results weighted by the sample size of each study were first calculated using a fixed-effects model.53 Pooled weighted results were also generated for important patient subsets, such as patients without prior MI and patients with severe coronary artery disease as defined in each report. We also explored the effect of varying positivity criteria on pooled results. For the analysis, positivity criteria were grouped according to whether an abnormal test result required that an abnormality manifested after exercise vs either at rest or after exercise. If not fully specified, a less stringent criterion of abnormality at rest or after exercise was used. In addition, exercise ECHO studies were grouped as requiring either new regional wall motion abnormalities (RWMAs) or new or worse RWMAs. All results are presented as percentage sensitivity and specificity with 95% confidence intervals (CIs).
SROC Analysis for Each Diagnostic Test
Receiver operating characteristic curves graphically represent the true-positive and false-positive ratios for a diagnostic test when the threshold for a positive test result is varied.54 The area under the curve summarizes the overall diagnostic performance of the test, with larger areas corresponding to a more discriminating test. An area of 0.5 corresponds to a test whose results are no better than chance, while an area of 1.0 denotes a perfect test. SROC analysis assumes that part of the variability in test performance reported in the literature is due to the use of different cut points or positivity criteria and adjusts for these differences. For example, a study of exercise ECHO may use a more stringent criterion such as development of a new RWMA to signal an abnormal test result or a more lenient criterion such as the absence of a hyperkinetic contractile response to exercise resulting in a different reported sensitivity and specificity. SROC analysis also allows adjustment for important clinical covariates and for comparison between different types of tests.55 In this last case, a variable corresponding to the type of exercise testing used (eg, exercise ECHO or exercise SPECT) is entered into the regression equation. The -coefficients for the variable give a measure of the difference in diagnostic performance of the 2 tests, with positive coefficients indicating better discriminatory power and negative coefficients corresponding to reduced discriminatory ability.
SROC curves were generated separately for each test. We assessed the influence of variables including publication year; proportion of patients with prior MI; indication or setting for the test; mean age; proportion of men in the study population; presence of verification bias; the angiographic definition of disease (50% stenosis vs 70% or 75%); type of exercise (treadmill vs other); positivity criterion; and in the case of exercise SPECT, type of nuclide (thallium vs technetium Tc 99m sestamibi) and type of analysis (visual vs quantitative) on test performance. We used a significance level of P<.05, implying that regression coefficients whose 95% CIs do not cross zero are statistically significant. Since multiple variables were tested, one would normally adjust P values for multiple comparisons, eg, with a Bonferroni correction. However, to minimize the chance of missing potential confounding factors, all explanatory variables with P <.05 were included in subsequent multivariate analyses. The Bonferroni-adjusted P values in our analyses were approximately .005; therefore, explanatory variables with .005<P<.05 should be interpreted with caution.
Data for some explanatory variables were not specified in all articles. For example, the proportion of prior percutaneous transluminal coronary angioplasty and CABG and the percentage of uninterpretable tests were excluded from all analyses due to missing data. Also, in the 1 article in which mean age was not given, in the 1 case in which the proportion of men was absent, in the 1 article in which the clinical setting for testing was not fully specified, and in the 2 articles in which the proportion of patients with MI was not specified, we used estimates for these variables based on a best subset regression analysis, so the widest range of literature could be included. Sensitivity analyses using weighted mean values for the missing data or excluding these articles from the analysis did not change the results substantively. Therefore, the base case including all articles is presented.
We then assessed which explanatory variables were significant in multivariate analysis for each test using stepwise forward regression analysis with backward elimination including all variables. All variables with a P<.05 were kept in the model. Variables with .05<P<.10 were kept in the model if they substantially increased the explanatory power of the model.
Comparison SROC Analyses Between Diagnostic Tests
SROC curves were performed comparing exercise ECHO to exercise SPECT, exercise ECHO to exercise ECG, and exercise SPECT to exercise ECG. In each case, all explanatory variables were once again tested along with the variable indicating the test comparison. We then performed multivariate stepwise forward regression with backward elimination including all variables with P<.05 in the step above as well as all variables significant in multivariate analysis for each individual test. To develop a parsimonious model with similar explanatory variables across all comparisons, we included in the final models significant variables with similar effects for all tests as well as interaction terms to account for significant variables with effects specific to a particular diagnostic test. Final models were tested for heterogeneity by comparing the values predicted by the model to the 95% CI of the actual values for each article. Similar SROC analyses were also performed in the following important subsets: studies comparing exercise ECHO and exercise SPECT directly in the same patients, patients without prior MI, and patients with severe disease as defined in each report.
RESULTS
Overview of Studies
A total of 902 citations published between January 1990 and October 1997 were screened, and 44 articles met inclusion criteria.3-8,14-51 The clinical characteristics of the studies analyzed are outlined in Table 1. Overall, 24 studies reported exercise ECHO results in 2637 patients with a weighted mean age of 59 years. The patients were predominantly men (69%). Significant coronary artery disease, as defined in each report, was present in 66% of patients and prior MI was present in 20% of patients. Twenty-seven studies reported exercise SPECT data on 3237 patients, of whom 70% were male, with a mean age of 59 years. Significant coronary artery disease was present in 78%, with past MI in 33%. In 24 articles on exercise ECHO and/or exercise SPECT, data on results of the exercise ECG in the same patient population were also given. These encompassed 2456 patients with a mean age of 59 years, of whom 66% were men. The prevalence of coronary artery disease was 69% with past MI in 20%.
|
|
|
|
Table 1.Clinical Characteristics of the Studies Included in the Meta-analysis*
|
|
|
Weighted Pooled Results
Diagnostic test performance for individual studies is outlined in Table 1. In pooled data weighted by the number of patients with and without disease in each study, exercise ECHO had a sensitivity (true-positive ratio) of 85% (95% CI, 83%-87%) with a specificity (1 - false-positive ratio) of 77% (95% CI, 74%-80%). The SPECT analyses yielded a similar sensitivity of 87% (95% CI, 86%-88%) but a lower specificity of 64% (95% CI, 60%-68%). Weighted pooled data for exercise ECG revealed a significantly lower sensitivity of 52% (95% CI, 50%-55%) and a specificity of 71% (95% CI, 68%-74%). When only patients without prior MI were considered, the sensitivity and specificity for exercise ECHO were similar to those of the cohort overall at 87% (95% CI, 84%-89%) and 84% (95% CI, 81%-88%). Weighted pooled results for SPECT in this subset were also similar to overall results with a sensitivity of 86% (95% CI, 83%-88%) and a specificity of 62% (95% CI, 55%-70%).
The criterion for severe disease varied from article to article but generally denoted multivessel disease. In patients with severe disease, the sensitivity for exercise ECHO rose to 92% (95% CI, 90%-94%) when any abnormal test result was considered positive, but the specificity also dropped significantly to 54% (95% CI, 50%-58%). In contrast, when only abnormalities in multiple coronary distributions were considered an abnormal test result, the sensitivity fell to 60% (95% CI, 53%-67%) while specificity rose to 88% (95% CI, 85%-92%). Similar trends were seen for exercise SPECT with a sensitivity of 92% (95% CI, 90%-94%) and a specificity of 21% (95% CI, 19%-24%) when any abnormality was considered a positive test result, but a sensitivity of 44% (95% CI, 38%-49%) and a specificity of 87% (95% CI, 85%-89%) when only abnormalities in multiple distributions were considered positive.
Pooled results were analyzed by positivity criteria as outlined in the "Methods" section and compared with the overall results. No significant differences in sensitivity were detected for either exercise ECHO or exercise SPECT. However, specificity in reports requiring an abnormality seen only after exercise rather than at rest or after exercise was significantly higher for exercise SPECT (76% [95% CI, 69%-83%] vs 61% [95% CI, 57%-65%]) and for exercise ECHO (84% [95% CI, 81%-87%] vs 70% [95% CI, 66%-74%]). Specificity was also higher for exercise ECHO reports requiring a new RWMA than for those using a new or worsened RWMA as a positivity criterion (93% [95% CI, 88%-98%) vs 75% [95% CI, 72%-78%]).
SROC Analysis for Each Diagnostic Test
In univariate analysis for exercise ECHO, age and publication year were significant predictors. The discriminatory power of the test diminished slightly with increasing mean age ( -coefficient, -0.22 per year; 95% CI, -0.31 to -0.12) and with later publication year (-0.41 per year; 95% CI, -0.58 to -0.24). Performance was better in reports requiring an abnormality seen only after exercise rather than at rest or after exercise (0.87; 95% CI, 0.005-1.74). Sex was not a significant predictor (0.40; 95% CI, -0.99 to 1.79). Similarly, increasing age (-0.15; 95% CI, -0.24 to -0.06) was a significant predictor of SPECT performance. Unlike exercise ECHO, settings that included known coronary artery disease vs suspected coronary artery disease only were associated with better discriminatory performance (1.14; 95% CI, 0.59-1.70) as were higher proportions of men in the study population (1.89; 95% CI, 0.72-3.07). No predictors were significant for exercise ECG.
In multivariate analysis, increasing age (-0.16; 95% CI, -0.23 to -0.09) remained a significant predictor of performance for exercise ECHO, as did a setting including known coronary artery disease (-0.56; 95% CI, -1.00 to -0.12). For exercise SPECT, a setting including known or suspected coronary artery disease (1.19; 95% CI, 0.67-1.70) in the study population was associated with improved performance. For both tests, performance diminished with later publication year with a parameter estimate of -0.27 (95% CI, -0.40 to -0.14) for ECHO and -0.15 (95% CI, -0.28 to -0.012) for SPECT. No explanatory variables were significant for exercise ECG in multivariate analysis.
Comparison SROC Analyses Between Diagnostic Tests
In a model comparing exercise ECHO performance to SPECT, exercise ECHO displayed significantly better discriminatory power (parameter estimate for incremental improvement, 1.18; 95% CI, 0.71-1.65), when adjusted for age, publication year, and a setting including known coronary artery disease for SPECT studies (Table 2). In models comparing the performance of exercise ECHO vs exercise ECG and exercise SPECT vs exercise ECG, both ECHO and SPECT performed significantly better than exercise ECG (Table 2). The incremental improvement was greater for ECHO than for SPECT. These results are presented graphically in Figure 1 and Figure 2. In the subset of reports (n=6) comparing exercise ECHO and exercise SPECT directly in the same patients, exercise ECHO also displayed better discriminatory performance parameter estimate (1.06; 95% CI, 0.77-1.36) in a model adjusted for age.
|
|
|
|
Table 2.Comparison SROC Analyses Between Diagnostic Tests*
|
|
|
|
|
|
|
Figure 1.Panel A shows summary receiver operating characteristic (SROC) curves for exercise single-photon emission computed tomography (SPECT) based on a model comparing exercise echocardiography (ECHO) and exercise SPECT. Panel B shows SROC curves for exercise ECHO based on model comparing exercise ECHO and exercise SPECT. Panel C shows SROC curves for exercise testing without adjunct imaging based on a model comparing exercise ECHO and exercise electrocardiography. In all panels, the horizontal axis represents the false-positive ratio (1 - specificity) and the vertical axis the true-positive ratio (sensitivity). The base case is adjusted to a population aged 59 years, publication year 1993, and a setting including known or suspected coronary artery disease (CAD) in half of the cases. Additional SROC curves represent the best case, which is adjusted to age 55 years, publication year 1990, and a setting including known or suspected CAD in all cases, and worst case, which is adjusted to age 65 years, publication year 1995, and a setting with suspected CAD only in all cases.
|
|
|
|
|
|
|
Figure 2.Comparative summary receiver operating characteristic curves are shown for exercise echocardiography (ECHO), exercise single-photon emission computed tomography (SPECT), and exercise testing without adjunct imaging. The horizontal axis represents the false-positive ratio (1 - specificity) and the vertical axis the true-positive ratio (sensitivity).
|
|
|
In patients without prior MI, results were qualitatively similar to the overall analysis. When exercise ECHO and exercise SPECT were compared in this subgroup, exercise ECHO had better discriminatory power (1.21; 95% CI, 0.57-1.85). Both exercise SPECT and exercise ECHO performed significantly better than exercise ECG in patients without prior MI, but the incremental improvement for exercise ECHO was larger (2.35; 95% CI, 1.79-2.91) than for exercise SPECT (1.36; 95% CI, 0.58-2.15). Results were also similar for models assessing diagnostic performance in patients with severe coronary artery disease as defined by each report. Exercise ECHO performed significantly better than exercise SPECT (parameter estimate, 0.91; 95% CI, 0.26-1.56). This result should be interpreted with caution, however, given the varying definitions of severe coronary artery disease from study to study and the relatively few studies in which these data were reported.
Testing for Heterogeneity
Final models were tested for heterogeneity by comparing the model predicted discriminatory power to the 95% CIs of the actual discriminatory power for each study. Analyses were homogeneous with the exception of the following data. In the models comparing exercise SPECT with either exercise ECHO or exercise ECG in the overall cohort, SPECT data from Solot et al29 fell outside the predicted parameters, likely related to the very high sensitivity (97%) reported in this cohort with one specific SPECT imaging filter. In addition, in the comparison of exercise ECHO to exercise SPECT, ECHO data from Crouse et al38 and SPECT data from Van Train et al32 showing very high sensitivity fell outside predicted values. In models comparing exercise ECG with either exercise ECHO or exercise SPECT, exercise ECG data from Sylven et al30 fell outside the predicted parameters, due primarily to a very high false-positive ratio (90%) associated with the cutoff used. In models concerning diagnostic performance for severe disease, these reports also fell outside predicted values, as did exercise ECHO data from Ryan et al49 and Roger et al48 and SPECT data from Oguzhan et al.26 Models in the subset of patients without prior MI were all homogeneous.
COMMENT
The current study presents a meta-analysis of the contemporary literature on exercise ECHO and exercise SPECT imaging. Our analysis suggests that both exercise ECHO and exercise SPECT imaging have similar sensitivities but that exercise ECHO has lower false-positive ratios and, thus, higher specificity. As a result, the discriminatory ability of exercise ECHO was significantly higher than that of exercise SPECT.
Our data also show that both exercise SPECT imaging and exercise ECHO have significantly better discriminatory capabilities than exercise ECG in these patient populations, although the incremental improvement in performance is greater for exercise ECHO. Detrano et al56 have suggested in previous meta-analyses of exercise testing that the incremental value of imaging may be overestimated when data on exercise ECG are drawn from reports in which exercise ECG is compared to a "better" test. This may, in part, be related to study of cohorts enriched for patients with baseline echocardiographic abnormalities or other conditions affecting accuracy of the exercise ECG. In addition, the data on exercise ECG in reports focusing on an imaging modality may not include detailed information on important variables such as exercise duration, symptoms, or degree of ST-segment changes. They do, however, represent contemporaneous data on exercise ECG results in the same clinical cohorts. Our estimates of the performance of exercise ECG lie within the 95% CIs generated in the meta-analysis by Detrano et al and are unlikely to give qualitatively varying results. In actual clinical practice, the performance of an imaging test such as SPECT or ECHO with exercise is not pitted against the performance of standard exercise testing but, rather, is used in conjunction with information from the exercise test to enhance its diagnostic and prognostic capabilities.57
Performance for exercise ECHO and exercise SPECT in the subset of patients without evidence of prior MI was similar to that for each test in the cohort overall. Interestingly, however, in multivariate analysis, a setting with known or suspected coronary artery disease (a proxy for pretest probability of disease) was associated with somewhat lower discriminatory power for exercise ECHO but led to improved discrimination for exercise SPECT. These findings may be related to the differing nature of exercise ECHO, which relies on the functional response of the myocardium to exercise, and exercise SPECT, in which perfusion is gauged as normal or abnormal. For example, the baseline RWMA associated with prior infarction may make interpretation of exercise ECHO more difficult if a positivity criterion requiring development of new or worsening RWMA after exercise is used but may not influence interpretation of perfusion in an identical fashion. The findings may also relate to differences in positivity criteria, although the SROC methods used should adjust for this in large part.
Although these data suggest that exercise ECHO performs as well or better than exercise myocardial perfusion scintigraphy with SPECT imaging, an alternative interpretation should be considered. Several studies have reported that the specificity of diagnostic tests decreases with time as the test is used more widely in clinical decision making and is applied to a wider spectrum of patient populations.58-60 This is consistent with our finding that publication year is a significant predictor of the performance of each test and that discriminatory power decreases in more recent reports. Since myocardial perfusion scintigraphy has been in widespread clinical use since the early 1980s and as exercise ECHO has become popular more recently, the difference in specificity seen could be a function of this different experience. However, in the subset of studies comparing the 2 modalities directly in the same patients, exercise ECHO performed significantly better, mitigating against this possibility. These direct comparisons may still be influenced by verification bias (also known as posttest referral bias) and the tendency to confirm noninvasive test findings more frequently in patients with abnormal test results, but the degree of bias should be similar for the 2 tests.
Several technical factors related to test performance were not significant predictors of discriminatory ability, although pairs of sensitivity and specificity can still be different in that they may be shifted along the same receiver operating characteristic curve. For example, the distinction between bicycle and treadmill exercise was not a significant predictor of exercise ECHO performance, suggesting that both can give similar results. Similarly, variables comparing thallium stress test with technetium Tc 99m sestamibi or distinguishing visual from quantitative or computer-based interpretation of exercise SPECT were also not significant in the current analysis.
Some limitations of the literature reviewed deserve note. Information on the incidence of uninterpretable test results for either imaging modality was often sketchy or absent. In some reports, patients with inadequate imaging were excluded from the analysis, inflating diagnostic test performance and obviating meaningful adjustment for this parameter. Some insight may be gained from the large series comparing the 2 modalities head to head in the same patients by Quinones et al.7 In this series of 292 patients, 99% of ECHO and 100% of SPECT studies were adequate for interpretation. Information on other potentially important factors such as test performance in relation to sex or body size was also rarely given. Verification bias remains a concern since recent studies60 suggest substantial effects on reported sensitivities and specificities, although the likely presence or absence of verification bias was not a significant predictor for the comparison of exercise SPECT and exercise ECHO. Ongoing technological developments for both tests may also affect test performance. For example, recent reports using gated SPECT imaging suggest this technique can enhance specificity for the diagnosis of coronary artery disease,61-62 particularly in patient subsets prone to artifact, such as women.63 Despite these limitations, an aggregate of the contemporary literature likely represents the best factual information available regarding exercise imaging.
Our conclusions should also be viewed in light of study design considerations that could influence results. Meta-analysis of diagnostic tests may be subject to publication bias. That is, reports that present the diagnostic test under study in a favorable light may more likely be submitted and published than those showing little or no benefit. However, this bias affects the literature for both exercise SPECT and exercise ECHO and visual inspection of a plot of study size vs discriminatory power for each test indicated little systematic bias. Our analysis uses partially dependent data in that multiple tests were performed in some patients, but a sensitivity analysis randomly selecting 1 test per study yielded similar results. The analysis focuses on diagnostic test performance for coronary artery disease and does not incorporate potential differences in prognostic capabilities. Finally, these results cannot be fully generalized to a number of important subgroups, such as patients undergoing pharmacologic stress testing with adjunctive imaging or those undergoing exercise ECHO or exercise SPECT for other indications, such as risk stratification after recent angioplasty or MI. Because our search was conducted in English-language literature and reports were retrieved primarily from the United States and Canada, our conclusions may also be applicable primarily to practice in those countries.
Our analysis of the current literature shows that exercise ECHO and exercise SPECT have similar sensitivities for the detection of coronary artery disease; however, that exercise ECHO has better specificity and higher overall discriminatory capabilities as used in contemporary practice. Previous individual studies have had limited power to detect differences in the performance of the 2 tests, but in aggregate, these differences become significant. While exercise ECHO may, therefore, be preferable in most instances, the clinician's ultimate choice of imaging modality must take into account other important factors such as local expertise and experience with each test, availability, and cost.
AUTHOR INFORMATION
Kirsten E. Fleischmann, MD, MPH, is the recipient of a Clinical Investigator Development Award (1K08HL02964-01) from the National Heart, Lung and Blood Institute, Bethesda, Md. Dr Fleischmann and Ms Kuntz were also supported by a project grant from the American Society of Echocardiography. Dr Hunink was supported by a Persoongerichte Impuls voor Onderzoeksgroepen met Nieuwe Ideeen voor Excellente Research (PIONIER) award from the Netherlands Organization for Scientific Research, the Hague, Netherlands.
The authors thank Finn Mannting, MD, for his thoughtful comments.
Corresponding author: Kirsten E. Fleischmann, MD, MPH, Cardiovascular Division, University of California, San Francisco, Medical Center, 505 Parnassus Ave, San Francisco, CA 94143-0214 (e-mail: Fleischm{at}cardio.ucsf.edu).
From the Cardiology Division, University of California, San Francisco, Medical Center, San Francisco (Dr Fleischmann); and the Section for Clinical Epidemiology (Dr Kuntz), Brigham and Women's Hospital, and the Cardiovascular Division (Dr Douglas), Beth Israel Deaconess Medical Center, Harvard Medical School, and the Department of Health Policy and Management (Drs Hunink and Kuntz), Harvard School of Public Health, Boston, Mass; and the Departments of Epidemiology and Biostatistics and Radiology, Erasmus University, Rotterdam, the Netherlands (Dr Hunink).
REFERENCES
 |  |
1. Farmer JA, Gotto AM. Risk factors for coronary artery disease. In: Braunwald E, ed. Heart Disease: A Textbook of Cardiovascular Medicine. Philadelphia, Pa: Saunders; 1992:1125-1160.
2. Hunink MG, Goldman L, Tosteson AN, et al. The recent decline in mortality from coronary heart disease, 1980-1990: the effect of secular trends in risk factors and treatment. JAMA. 1997;277:535-542.
FREE FULL TEXT
3. Hecht HS, DeBord L, Shaw R, et al. Supine bicycle stress echocardiography versus tomographic thallium-201 exercise imaging for the detection of coronary artery disease. J Am Soc Echocardiogr. 1993;6:177-185.
PUBMED
4. Hoffmann R, Lethen H, Kleinhans E, Weiss M, Flachskampf FA, Hanrath P. Comparative evaluation of bicycle and dobutamine stress echocardiography with perfusion scintigraphy and bicycle electrocardiogram for identification of coronary artery disease. Am J Cardiol. 1993;72:555-559.
FULL TEXT
|
ISI
| PUBMED
5. Marwick TH, D'Hondt AM, Mairesse GH, et al. Comparative ability of dobutamine and exercise stress in inducing myocardial ischaemia in active patients. Br Heart J. 1994;72:31-38.
FREE FULL TEXT
6. Pozzoli MMA, Fioretti PM, Salustri A, Reijs AE, Roelandt JR. Exercise echocardiography and technetium-99m MIBI single-photon emission computed tomography in the detection of coronary artery disease. Am J Cardiol. 1991;67:350-355.
FULL TEXT
|
ISI
| PUBMED
7. Quinones MA, Verani MS, Haichin RM, Mahmarian JJ, Suarez J, Zoghbi WA. Exercise echocardiography versus 201TI single-photon emission computed tomography in evaluation of coronary artery disease: analysis of 292 patients. Circulation. 1992;85:1026-1031.
FREE FULL TEXT
8. Salustri A, Pozzoli MM, Hermans, et al. Relationship between exercise echocardiography and perfusion SPECT in patients with single-vessel coronary artery disease. Am Heart J. 1992;124:75-83.
FULL TEXT
|
ISI
| PUBMED
9. O'Keefe JH Jr, Barnhart CS, Bateman TM. Comparison of stress echocardiography and stress myocardial perfusion scintigraphy for diagnosing coronary artery disease and assessing its severity. Am J Cardiol. 1995;75:25D-34D.
10. Littenberg B, Moses LE. Estimating diagnostic accuracy from multiple conflicting reports: a new meta-analytic method. Med Decis Making. 1993;13:313-321.
FREE FULL TEXT
11. Moses LE, Shapiro D, Littenberg B. Combined independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations. Stat Med. 1993;12:1293-1316.
ISI
| PUBMED
12. Irwig L, Tosteson ANA, Gatsonis C, et al. Guidelines for meta-analyses evaluating diagnostic tests. Ann Intern Med. 1994;120:667-676.
FREE FULL TEXT
13. Alam M, Hoglund C, Thorstrand C, Carlens P. Effects of exercise on the displacement of the atrioventricular plane in patients with coronary artery disease: a new echocardiographic method of detecting reversible ischaemia. Eur Heart J. 1991;12:760-765.
ISI
| PUBMED
14. Berman DS, Kiat H, Friedman JD, et al. Separate acquisition rest Thallium-201/stress technetium-99m Sestamibi dual-isotope myocardial perfusion single-photon emission computer tomography: a clinical validation study. J Am Coll Cardiol. 1993;22:1455-1464.
ABSTRACT
15. Chae SC, Heo J, Iskandrian AS, Wasserleben V, Cave V. Identification of extensive coronary artery disease in women by exercise single-photon emission computed tomography (SPECT) thallium imaging. J Am Coll Cardiol. 1993;21:1305-1311.
ABSTRACT
16. Christian TF, Miller TD, Bailey KR, Gibbons RJ. Noninvasive identification of severe coronary artery disease using exercise tomographic thallium-201 imaging. Am J Cardiol. 1992;70:14-20.
FULL TEXT
|
ISI
| PUBMED
17. Fleming RM, Kirkeeide RL, Taegtmeyer H, et al. Comparison of technetium-99m teboroxime tomography with automated quantitative coronary arteriography and thallium-201 tomographic imaging. J Am Coll Cardiol. 1991;17:1297-1302.
ABSTRACT
18. Gupta NC, Esterbrooks DJ, Hilleman DE, Mohiuddin SM. Comparison of adenosine and exercise thallium-201 single-photon emission computed tomography (SPECT) myocardial perfusion imaging. J Am Coll Cardiol. 1992;19:248-257.
ABSTRACT
19. Hambye AS, Vervaet A, Lieber S, Ranquin R. Diagnostic value and incremental contribution of bicycle exercise, first-pass radionuclide angiography, and 99mTc-labeled sestamibi single-photon emission computed tomography in the identification of coronary artery disease in patients without infarction. J Nucl Cardiol. 1996;3:464-474.
FULL TEXT
|
ISI
| PUBMED
20. Heiba SI, Hayat NJ, Salman HS, et al. Technetium-99-MIBI myocardial SPECT: supine versus right lateral imaging and comparison with coronary arteriography. J Nucl Med. 1997;38:1510-1514.
FREE FULL TEXT
21. Ho YL, Wu CC, Huang PJ, et al. Dobutamine stress echocardiography compared with exercise thallium-201 single-photon emission computed tomography in detecting coronary artery disease-effect of exercise on level of accuracy. Cardiology. 1997;88:379-385.
ISI
| PUBMED
22. Kiat H, Van Train KF, Maddahi J, et al. Development and prospective application of quantitative 2-day stress-rest Tc-99m methoxy isobutyl isonitrile SPECT for the diagnosis of coronary artery disease. Am Heart J. 1990;120:1255-1266.
FULL TEXT
|
ISI
| PUBMED
23. Mahmarian JJ, Boyce TM, Goldberg RK, Cocanougher MK, Roberts R, Verani MS. Quantitative exercise thallium-201 single photon emission computed tomography for the enhanced diagnosis of ischemic heart disease. J Am Coll Cardiol. 1990;15:318-329.
ABSTRACT
24. Minoves M, Garcia A, Magrina J, Pavia J, Herranz R, Setoain J. Evaluation of myocardial perfusion defects by means of "bulls eye" images. Clin Cardiol. 1993;16:16-22.
ISI
| PUBMED
25. Nguyen T, Heo J, Ogilby JD, Iskandrian AS. Single photon emission computed tomography with thallium-201 during adenosine-induced coronary hyperemia: correlation with coronary arteriography, exercise thallium imaging and two-dimensional echocardiography. J Am Coll Cardiol. 1990;16:1375-1383.
ABSTRACT
26. Oguzhan A, Kisacik HL, Ozdemir K, et al. Comparison of exercise stress testing with dobutamine stress echocardiography and exercise technetium-99m isonitrile single photon emission computerized tomography for diagnosis of coronary artery disease. Jpn Heart J. 1997;38:333-344.
PUBMED
27. Palmas W, Friedman JD, Diamond GA, Silber H, Kiat H, Berman DS. Incremental value of simultaneous assessment of myocardial function and perfusion with technetium-99m Sestamibi for prediction of extent of coronary artery disease. J Am Coll Cardiol. 1995;25:1024-1031.
ABSTRACT
28. Rubello D, Zanco P, Candelpergher G, et al. Usefulness of 99mTc-MIBI stress myocardial SPECT bull's-eye quantification in coronary artery disease. Q J Nucl Med. 1995;39:111-115.
PUBMED
29. Solot G, Hermans J, Merlo P, et al. Correlation of 99Tcm-Sestamibi SPECT with coronary angiography in general hospital practice. Nucl Med Commun. 1993;14:23-29.
ISI
| PUBMED
30. Sylven C, Hagerman I, Ylen M, Nyquist O, Nowak J. Variance ECG detection of coronary artery disease: a comparison with exercise stress test and myocardial scintigraphy. Clin Cardiol. 1994;17:132-140.
ISI
| PUBMED
31. Taillefer R, DePuey EG, Udelson JE, et al. Comparative diagnostic accuracy of Tl-201 and Tc-99m Sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. J Am Coll Cardiol. 1997;29:69-77.
ABSTRACT
32. Van Train KF, Garcia EV, Maddahi J, et al. Multicenter trial validation for quantitative analysis of same-day rest-stress technetium-99m-sestamibi myocardial tomograms. J Nucl Med. 1994;35:609-618.
FREE FULL TEXT
33. Van Train KF, Areeda J, Garcia EV, et al. Quantitative same-day rest-stress technetium-99m-sestamibi SPECT: definition and validation of stress normal limits and criteria for abnormality. J Nucl Med. 1993;34:1494-1502.
FREE FULL TEXT
34. Van Train KF, Maddahi J, Berman DS, et al. Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: a multicenter trial. J Nucl Med. 1990;31:1168-1179.
FREE FULL TEXT
35. Beleslin BD, Ostojic M, Stepanovic J, et al. Stress echocardiography in the detection of myocardial ischemia. Circulation. 1994;90:1168-1176.
FREE FULL TEXT
36. Bjornstad K, Aakhus S, Hatle L. Comparison of digital dipyridamole stress echocardiography and upright bicycle stress echocardiography for identification of coronary artery stenosis. Cardiology. 1995;86:514-520.
ISI
| PUBMED
37. Cohen JL, Ottenweller JE, George AK, Duvvuri S. Comparison of dobutamine and exercise echocardiography for detecting coronary artery disease. Am J Cardiol. 1993;72:1226-1231.
FULL TEXT
|
ISI
| PUBMED
38. Crouse LJ, Harbrecht JJ, Vacek JL, Rosamond TL, Kramer PH. Exercise echocardiography as a screening test for coronary artery disease and correlation with coronary arteriography. Am J Cardiol. 1991;67:1213-1218.
FULL TEXT
|
ISI
| PUBMED
39. Dagianti A, Penco M, Agati L, et al. Stress echocardiography: comparison of exercise, dipyridamole and dobutamine in detecting and predicting the extent of coronary artery disease. J Am Coll Cardiol. 1995;26:18-25.
ABSTRACT
40. Galanti G, Sciagra R, Comeglio M, et al. Diagnostic accuracy of peak exercise echocardiography in coronary artery disease: comparison with thallium-201 myocardial scintigraphy. Am Heart J. 1991;122:1609-1616.
FULL TEXT
|
ISI
| PUBMED
41. Jun T, Guizhen A, Xiaoming W, Jijun C, Jing X. Exercise echocardiography: feasibility and value for detection of coronary artery disease. Chin Med J. 1996;109:381-384.
PUBMED
42. Luohtolati M, Saraste M, Hartiala J. Exercise echocardiography in the diagnosis of coronary artery disease. Ann Med. 1996;28:73-77.
ISI
| PUBMED
43. Marangelli V, Iliceto S, Piccinni G, De Martino G, Sorgente L, Rizzon P. Detection of coronary artery disease by digital stress echocardiography: comparison of exercise, transesophageal atrial pacing and dipyridamole echocardiography. J Am Coll Cardiol. 1994;24:117-124.
ABSTRACT
44. Marwick TH, Nemec JJ, Pashkow FJ, Stewart WJ, Salcedo EE. Accuracy and limitations of exercise echocardiography in a routine clinical setting. J Am Coll Cardiol. 1992;19:74-81.
ABSTRACT
45. Marwick TH, Anderson T, Williams MJ, et al. Exercise echocardiography is an accurate and cost-efficient technique for detection of coronary artery disease in women. J Am Coll Cardiol. 1995;26:335-341.
ABSTRACT
46. Marwick TH, Torelli J, Harjai K, et al. Influence of left ventricular hypertrophy on detection of coronary artery disease using exercise echocardiography. J Am Coll Cardiol. 1995;26:1180-1186.
ABSTRACT
47. Roger VL, Pellikka PA, Oh JK, Bailey KR, Tajik AJ. Identification of multivessel coronary artery disease by exercise echocardiography. J Am Coll Cardiol. 1994;24:109-114.
ABSTRACT
48. Roger VL, Pellikka PA, Bell MR, et al. Sex and test verification bias: impact on the diagnostic value of exercise echocardiography. Circulation. 1997;95:405-410.
FREE FULL TEXT
49. Ryan T, Segar DS, Sawada SG, et al. Detection of coronary artery disease with upright bicycle exercise echocardiography. J Am Soc Echocardiogr. 1993;6:186-197.
PUBMED
50. Tawa CB, Baker WB, Kleiman NS, et al. Comparison of adenosine echocardiography, with and without isometric handgrip, to exercise echocardiography in the detection of ischemia in patients with coronary artery disease. J Am Soc Echocardiogr. 1996;9:33-43.
FULL TEXT
| PUBMED
51. Williams MJ, Marwick TH, O'Gorman D, Foale RA. Comparison of exercise echocardiography with an exercise score to diagnose coronary artery disease in women. Am J Cardiol. 1994;74:435-438.
FULL TEXT
|
ISI
| PUBMED
52. Begg CB, Greenes A. Assessment of diagnostic tests when disease verification is subject to selection bias. Biometrics. 1983;39:207-215.
FULL TEXT
|
ISI
| PUBMED
53. Midgette AS, Stukel TA, Littenberg B. A meta-analytic method for summarizing diagnostic test performances: receiver operating characteristic summary point estimates. Med Decis Making. 1993;13:253-257.
FREE FULL TEXT
54. Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology. 1982;143:29-36.
FREE FULL TEXT
55. de Vries SO, Hunink MGM, Polak JF. Summary receiver-operating characteristic curves as a technique for meta-analysis of the diagnostic performance of duplex ultrasonography in peripheral arterial disease. Acad Radiol. 1996;3:361-369.
FULL TEXT
|
ISI
| PUBMED
56. Detrano R, Gianrossi R, Froelicher V. The diagnostic accuracy of the exercise electrocardiogram: a meta-analysis of 22 years of research. Prog Cardiovasc Dis. 1989;32:173-206.
FULL TEXT
|
ISI
| PUBMED
57. Kotler TS, Diamond GA. Exercise thallium-201 scintigraphy in the diagnosis and prognosis of coronary artery disease. Ann Intern Med. 1990;113:684-702.
FREE FULL TEXT
58. Rozanski A, Diamond GA, Berman D, Forrester JS, Morris D, Swan HJ. The declining specificity of exercise radionuclide ventriculography. N Engl J Med. 1983;309:518-522.
ABSTRACT
59. Detrano R, Janosi A, Lyons KP, Marcondes, Abbassi N. Factors affecting sensitivity and specificity of a diagnostic test: the exercise thallium scintigram. Am J Med. 1988;84:699-710.
FULL TEXT
|
ISI
| PUBMED
60. Roger V, Pellikka PA, Bell MR, Chow CWH, Bailey KR, Seward JB. Sex and test verification bias: impact on the diagnostic value of exercise echocardiography. Circulation. 1997;95:405-410.
FREE FULL TEXT
61. Depuey EG, Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med. 1995;36:952-955.
FREE FULL TEXT
62. Mannting F, Morgan-Mannting MG. Gated SPECT with technetium-99m-sestamibi for assessment of myocardial perfusion abnormalities. J Nucl Med. 1993;34:601-608.
FREE FULL TEXT
63. Taillefer R, Depuey EG, Udelson JE, Beller GA, Latour Y, Reeves F. Comparative diagnostic accuracy of Tl-201 and Tc-99m Sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. J Am Coll Cardiol. 1997;29:69-77.
ABSTRACT
CiteULike Connotea Del.icio.us Digg Reddit Technorati
What's this?
RELATED LETTER
Exercise Echocardiography vs Exercise SPECT Testing
Christine Z. Dickinson, Howard J. Dworkin, James H. O'Keefe, Jr, Timothy M. Bateman, Raymond J. Gibbons, Steven Kymes, Leslee Shaw, James Fletcher, Kirsten E. Fleischmann, Maria G. M. Hunink, Karen M. Kuntz, and Pamela S. Douglas
JAMA. 1999;282(17):1621-1623.
EXTRACT
| FULL TEXT
THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES
 |
Multimodality Cardiac Stress Testing: Combining Real-Time 3-Dimensional Echocardiography and Myocardial Perfusion SPECT
Walimbe et al.
JNM 2009;50:226-230.
ABSTRACT
| FULL TEXT
Diagnostic Performance of Coronary Angiography by 64-Row CT
Miller et al.
NEJM 2008;359:2324-2336.
ABSTRACT
| FULL TEXT
Methods and Limitations of Assessing New Noninvasive Tests: Part I: Anatomy-Based Validation of Noninvasive Testing
Hachamovitch and Di Carli
Circulation 2008;117:2684-2690.
FULL TEXT
A randomized cross-over study for evaluation of the effect of image optimization with contrast on the diagnostic accuracy of dobutamine echocardiography in coronary artery disease The OPTIMIZE Trial.
Plana et al.
J Am Coll Cardiol Img 2008;1:145-152.
ABSTRACT
| FULL TEXT
MR perfusion imaging. What will be its impact for detection of coronary disease in the future?
Gerber
Eur Heart J 2008;29:434-435.
FULL TEXT
Indications for Revascularization
Brown et al.
Card Surg Adult 2008;3:551-572.
FULL TEXT
Automated coupled-contour and robust myocardium tracking in stress echocardiography
Karagiannis et al.
Eur J Echocardiogr 2007;8:431-437.
ABSTRACT
| FULL TEXT
Impact of Myocardial Perfusion Imaging with PET and 82Rb on Downstream Invasive Procedure Utilization, Costs, and Outcomes in Coronary Disease Management
Merhige et al.
JNM 2007;48:1069-1076.
ABSTRACT
| FULL TEXT
Diagnostic Accuracy of Rubidium-82 Myocardial Perfusion Imaging With Hybrid Positron Emission Tomography/Computed Tomography in the Detection of Coronary Artery Disease
Sampson et al.
J Am Coll Cardiol 2007;49:1052-1058.
ABSTRACT
| FULL TEXT
ACCF/AHA 2007 Clinical Expert Consensus Document on Coronary Artery Calcium Scoring By Computed Tomography in Global Cardiovascular Risk Assessment and in Evaluation of Patients With Chest Pain: A Report of the American College of Cardiology Foundation Clinical Expert Consensus Task Force (ACCF/AHA Writing Committee to Update the 2000 Expert Consensus Document on Electron Beam Computed Tomography) Developed in Collaboration With the Society of Atherosclerosis Imaging and Prevention and the Society of Cardiovascular Computed Tomography
Greenland et al.
J Am Coll Cardiol 2007;49:378-402.
FULL TEXT
Assessing Mature Technology: What Is the Effect of High-Quality Risk Stratification Evidence With Exercise Echocardiography and Single-Photon Emission Computed Tomography Imaging?
Shaw et al.
J Am Coll Cardiol 2007;49:238-239.
FULL TEXT
Screening for Coronary Artery Disease After Mediastinal Irradiation for Hodgkin's Disease
Heidenreich et al.
JCO 2007;25:43-49.
ABSTRACT
| FULL TEXT
Selecting optimal non-invasive cardiac imaging stress test in intermediate-risk patients using cost effectiveness analysis
Poldermans and Bax
Eur Heart J 2006;27:2378-2379.
FULL TEXT
Incremental cost-effectiveness of exercise echocardiography vs. SPECT imaging for the evaluation of stable chest pain
Shaw et al.
Eur Heart J 2006;27:2448-2458.
ABSTRACT
| FULL TEXT
Stress echocardiography is superior to exercise ECG in the risk stratification of patients presenting with acute chest pain with negative Troponin
Jeetley et al.
Eur J Echocardiogr 2006;7:155-164.
ABSTRACT
| FULL TEXT
Noninvasive Screening for Coronary Artery Disease With Computed Tomography Is Useful
Clouse et al.
Circulation 2006;113:125-146.
FULL TEXT
Stress Echocardiography: Current Methodology and Clinical Applications
Armstrong and Zoghbi
J Am Coll Cardiol 2005;45:1739-1747.
ABSTRACT
| FULL TEXT
Stress echocardiography for the diagnosis and risk stratification of patients with suspected or known coronary artery disease: a critical appraisal. Supported by the British Society of Echocardiography
Senior et al.
Heart 2005;91:427-436.
ABSTRACT
| FULL TEXT
Ventilation-Perfusion Scanning and Helical CT in Suspected Pulmonary Embolism: Meta-Analysis of Diagnostic Performance
Hayashino et al.
Radiology 2005;234:740-748.
ABSTRACT
| FULL TEXT
Utility of Stress Testing and Coronary Calcification Measurement for Detection of Coronary Artery Disease in Women
Nasir et al.
Arch Intern Med 2004;164:1610-1620.
ABSTRACT
| FULL TEXT
Non-invasive imaging for coronary artery disease in diabetes
Tschoepe and Burchert
British Journal of Diabetes & Vascular Disease 2004;4:245-250.
ABSTRACT
Implication of Prognostically Significant Negative Results on Prone SPECT
Lee et al.
JNM 2003;44:1641-1643.
FULL TEXT
Prognostic significance of impairment of heart rate response to exercise: Impact of left ventricular function and myocardial ischemia
Elhendy et al.
J Am Coll Cardiol 2003;42:823-830.
ABSTRACT
| FULL TEXT
Clinical and economic impact of exercise electrocardiography and exercise echocardiography in clinical practice
Marwick et al.
Eur Heart J 2003;24:1153-1163.
ABSTRACT
| FULL TEXT
Relation Between Platelet Response to Exercise and Coronary Angiographic Findings in Patients With Effort Angina
Lanza et al.
Circulation 2003;107:1378-1382.
ABSTRACT
| FULL TEXT
Indications for Coronary Revascularization
Sundt et al.
Card Surg Adult 2003;2:541-559.
FULL TEXT
Prognostic value of coronary blood flow velocity and myocardial perfusion in intermediate coronary narrowings and multivessel disease
Chamuleau et al.
J Am Coll Cardiol 2002;39:852-858.
ABSTRACT
| FULL TEXT
Contrast echocardiography and medical economics: looking into the crystal ball
Distante et al.
Eur Heart J Suppl 2002;4:C39-C47.
ABSTRACT
Cardiovascular Effects of Sildenafil During Exercise in Men With Known or Probable Coronary Artery Disease: A Randomized Crossover Trial
Arruda-Olson et al.
JAMA 2002;287:719-725.
ABSTRACT
| FULL TEXT
Current Results and New Developments of Coronary Angiography With Use of Contrast-Enhanced Computed Tomography of the Heart
Gerber et al.
Mayo Clin Proc. 2002;77:55-71.
ABSTRACT
Noninvasive Assessment of the Diabetic Patient for Coronary Artery Disease
Inzucchi
Diabetes Care 2001;24:1519-1521.
FULL TEXT
Noninvasive Tests in Patients with Stable Coronary Artery Disease
Lee and Boucher
NEJM 2001;344:1840-1845.
FULL TEXT
Electron-Beam Computed Tomography in the Diagnosis of Coronary Artery Disease: A Meta-analysis
Nallamothu et al.
Arch Intern Med 2001;161:833-838.
ABSTRACT
| FULL TEXT
Testing our tests: surrogate end points versus driving patient management and outcomes
Udelson
J Am Coll Cardiol 2001;37:89-92.
FULL TEXT
Stress testing and electron beam computed tomography for evaluation of patients with suspected coronary artery disease
Danias
J Am Coll Cardiol 2001;37:334-335.
FULL TEXT
Evaluating coronary artery disease--where does EBCT fit in?
Sheppard and Eisenberg
J Am Coll Cardiol 2001;37:335-336.
FULL TEXT
Evaluating coronary artery disease--where does EBCT fit in?: Reply
Shavelle and Budoff
J Am Coll Cardiol 2001;37:336-337.
FULL TEXT
American College of Cardiology/American Heart Association Expert Consensus Document on Electron-Beam Computed Tomography for the Diagnosis and Prognosis of Coronary Artery Disease : Committee Members
O'Rourke et al.
Circulation 2000;102:126-140.
FULL TEXT
Exercise testing and electron beam computed tomography in the evaluation of coronary artery disease
Shavelle et al.
J Am Coll Cardiol 2000;36:32-38.
ABSTRACT
| FULL TEXT
Peripheral Arterial Disease: Gadolinium-enhanced MR Angiography versus Color-guided Duplex US-A Meta-analysis
Visser and Myriam Hunink
Radiology 2000;216:67-77.
ABSTRACT
| FULL TEXT
Emergency Department Triage Strategies for Acute Chest Pain Using Creatine Kinase-MB and Troponin I Assays: A Cost-Effectiveness Analysis
Polanczyk et al.
ANN INTERN MED 1999;131:909-918.
ABSTRACT
| FULL TEXT
Exercise Echocardiography vs Exercise SPECT Testing
Dickinson et al.
JAMA 1999;282:1621-1623.
FULL TEXT
Noninvasive Imaging for the Diagnosis of Coronary Artery Disease: Focusing the Development of New Diagnostic Technology
Hunink et al.
ANN INTERN MED 1999;131:673-680.
ABSTRACT
| FULL TEXT
Lessons Learned From Studies of the Standard Exercise ECG Test
Froelicher et al.
Chest 1999;116:1442-1451.
FULL TEXT
ACC/AHA/ACP-ASIM guidelines for the management of patients with chronic stable angina: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Management of Patients With Chronic Stable Angina)
Gibbons et al.
J Am Coll Cardiol 1999;33:2092-2197.
FULL TEXT
Cost-Effectiveness of Diagnostic Strategies for Patients with Chest Pain
Kuntz et al.
ANN INTERN MED 1999;130:709-718.
ABSTRACT
| FULL TEXT
Cost-Effectiveness of Alternative Test Strategies for the Diagnosis of Coronary Artery Disease
Garber and Solomon
ANN INTERN MED 1999;130:719-728.
ABSTRACT
| FULL TEXT
|