You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT JAMA
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 292 No. 22, December 8, 2004 TABLE OF CONTENTS
  JAMA
  •  Online Features
  Original Contribution
 This Article
 •Abstract
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on ISI (101)
 •Contact me when this article is cited
 Related Content
 •Related article
 •Similar articles in JAMA
 Topic Collections
 •Revascularization
 •Surgical Interventions
 •Cardiovascular/ Cardiothoracic Surgery
 •Randomized Controlled Trial
 •Cardiovascular Disease/ Myocardial Infarction
 •Cardiovascular Intervention
 •Alert me on articles by topic

Sirolimus-Eluting vs Uncoated Stents for Prevention of Restenosis in Small Coronary Arteries

A Randomized Trial

Diego Ardissino, MD; Claudio Cavallini, MD; Ezio Bramucci, MD; Ciro Indolfi, MD; Antonio Marzocchi, MD; Antonio Manari, MD; Giulia Angeloni, MD; Giuseppe Carosio, MD; Erminio Bonizzoni, BSc, PhD; Stefania Colusso, RN; Monica Repetto, BSc; Piera Angelica Merlini, MD; for the SES-SMART Investigators

JAMA. 2004;292:2727-2734.

ABSTRACT

Context  Percutaneous coronary revascularization of small vessels is associated with a high restenosis rate. Sirolimus-eluting stents reduce restenosis in simple and previously untreated lesions of large coronary arteries, but their outcomes in small vessels have not been adequately investigated.

Objective  To determine whether sirolimus-eluting stents are associated with a reduced 8-month rate of angiographic restenosis in comparison with an uncoated stent.

Design, Setting, and Patients  This was a randomized, multicenter, single-blind, prospective trial performed with 257 patients undergoing percutaneous coronary revascularization for ischemic heart disease, and who had a previously untreated atherosclerotic lesion located in a small segment with a diameter of 2.75 mm or less, in 20 Italian centers between August 2002 and December 2003.

Intervention  Patients were randomly assigned to receive a sirolimus-eluting stent (129 patients) or an uncoated stent having an identical architecture and radiographic appearance (128 patients).

Main Outcome Measures  The primary end point was the 8-month binary in-segment restenosis rate; secondary end points included procedural success and the 8-month rate of major adverse cardiac and cerebrovascular events.

Results  The mean (SD) reference diameter of the treated segment was 2.2 (0.28) mm; the lesion length, 11.84 (6.15) mm. After 8 months, the binary in-segment restenosis rate was 53.1% (60/113) in the patients receiving an uncoated stent and 9.8% (12/123) in those receiving a sirolimus-eluting stent (relative risk [RR], 0.18; 95% confidence interval [CI], 0.10-0.32; P<.001). Fewer patients randomized to sirolimus-eluting stents experienced major adverse cardiac events (12/129 [9.3%] vs 40/128 [31.3%]; RR, 0.30; 95% CI, 0.15-0.55; P<.001) mainly because of a reduction in target lesion revascularization (9/129 [7%] vs 27/128 [21.1%]; RR, 0.33; 95% CI, 0.14-0.70; P = .002) and myocardial infarction (2/129 [1.6%] vs 10/129 [7.8%]; RR, 0.20; 95% CI, 0.01-0.93; P = .04).

Conclusion  The use of sirolimus-eluting stents to treat atherosclerotic lesions in small coronary arteries reduces restenosis and may also reduce major adverse cardiac events.



INTRODUCTION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Atherosclerotic lesions of small coronary arteries are frequently found in patients undergoing revascularization.1-5 However, the revascularization of small coronary arteries is a problem for bypass surgery because it is technically difficult and associated with a high failure and mortality rate6-7 and for percutaneous coronary revascularization because it is associated with high rates of acute complications and restenosis after standard balloon angioplasty1-3 and stent implantation.4-5

It has been shown that sirolimus-eluting stents reduce angiographic restenosis and improve the rate of event-free survival in patients who have coronary artery disease and are at low risk of restenosis.8 More recent reports have also shown the efficacy of drug-eluting stents under more challenging conditions such as long and complex lesions, and post hoc analyses of trial subpopulations suggest that drug-eluting stents may also effectively prevent restenosis in small vessels.9-11

This randomized, multicenter, prospective trial was designed to test the hypothesis that the implantation of a sirolimus-eluting stent in small coronary arteries is associated with a reduced 8-month rate of angiographic restenosis in comparison with the implantation of an uncoated stent having an identical architecture.


METHODS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Patients

Eligible patients had to be aged 18 years or older, with a documented diagnosis of acute coronary syndrome (without persistent ST-segment elevation), stable angina pectoris, or silent myocardial ischemia as shown by exercise stress test. Additional eligibility criteria were the presence of a single, previously untreated 50% to 99% target lesion in a native coronary artery 2.75 mm in diameter or less, which could be completely covered by a single stent (maximum length, 33 mm). The patients could have had single-vessel or multivessel disease but, in the latter case, had to have the nonrandomized lesion located in other coronary vessels.

Major exclusion criteria were recent ST-segment elevation acute coronary syndrome (within the previous 15 days), severe calcifications or thrombus-containing lesions, a left ventricular ejection fraction less than 30%, and known allergies to aspirin, clopidogrel, ticlopidine, heparin, stainless steel, contrast agents, or sirolimus. The study protocol was approved by the ethics committee of each participating center, and all patients gave written informed consent.

Randomization and Interventions

Online quantitative coronary angiography confirming vessel diameter and lesion-length enrollment criteria was performed before randomization. An automated telephone randomization system was used to assign the patients to treatment with a sirolimus-eluting stent (Cypher balloon-expandable stent; Cordis, Miami Lakes, Fla) or an uncoated stent of identical architecture and radiographic appearance (Bx Sonic balloon-expandable stent; Cordis), in a 1:1 ratio according to a centralized list. The randomization list was generated for a completely randomized design, ie, without blocks or stratification factors, using the SAS PLAN (SAS Institute Inc, Cary, NC) procedure. The investigators had to digitize patient date of birth, site number, vessel size, and stent length by means of an interactive voice recording system to obtain the assigned treatment. Data were confirmed by fax, which was included in the case report form.

Diameters of both types of stents were 2.25, 2.50, and 2.75 mm, and lengths were 8, 13, 18, 23, 28, and 33 mm. The 2 types of stents were visually and angiographically indistinguishable. The lesions were treated by using standard interventional techniques, including mandatory balloon dilatation before stent placement.

Before the index procedure, all patients received oral aspirin once daily and clopidogrel (a loading dose of 300 mg at least 2 hours before the procedure). Patients who had been pretreated with ticlopidine (250 mg twice a day) or clopidogrel (75 mg once daily) for at least 72 hours did not receive a clopidogrel loading dose. During the procedure, heparin was given as a bolus at 70 U/kg, with additional boluses to maintain an activated clotting time of more than 250 seconds. The use of glycoprotein IIb/IIIa inhibitors was encouraged but left to the discretion of the attending physician. Heparin administration was discontinued immediately after the procedure.

A 12-lead electrocardiogram was obtained before the procedure, immediately afterward, and 24 hours later or at discharge if earlier. Cardiac enzymes creatine kinase (CK) and CK-MB were evaluated twice within 8 to 16 and 18 to 24 hours of the procedure or at hospital discharge if earlier. Discharged patients received a regimen of aspirin (100 mg once daily indefinitely) and clopidogrel (75 mg once daily for at least 2 months). All patients were clinically followed up after 1 and 8 months by the trial coordinator at each site. Follow-up coronary angiography was performed after a mean (SD) of 8 (0.5) months.

Quantitative Coronary Angiography

Coronary angiograms obtained at baseline, on completion of the stenting procedure, and after 8 months were analyzed with a computer-based algorithm developed by MEDIS (version 5.1) (MEDIS, Medical Imaging System, Leiden, the Netherlands). The projection that best showed the stenosis in its tightest view was used for all angiograms; all details of the angiographic procedure were recorded in the case report forms. For standardization, each angiogram sequence was preceded by an intracoronary injection of 200 µg of nitroglycerin. Quantitative angiographic analyses were performed by 1 experienced cardiologist who was blinded to the patient’s identity, type of stent used, outcome, and film sequence. The minimal luminal diameter (MLD) and the nearest normal reference diameter (RVD) were measured in millimeters by using the catheter as a scaling factor. Percentage of stenosis was calculated as 100 (1 – MLD/RVD). Binary restenosis was defined as a stenosis of more than 50% of the MLD in the target lesion at angiographic follow-up. Acute gain was defined as the difference between the MLD after stent implantation and baseline MLD. Late luminal loss was defined as the difference between the MLD at the end of the stenting procedure and that measured during follow-up. The late loss index was defined as late loss divided by acute gain. Quantitative angiographic measurements of the target lesion were obtained in the "in-stent" zone (including only the stent segment) and in the "in-segment" zone (including the stented segment and the 5-mm margins proximal and distal to the stent); intraobserver and interobserver variabilities of the quantitative assessments have been previously reported.12

Outcomes

The primary end point of the study was the 8-month angiographic binary in-segment restenosis rate. Secondary end points were procedural success, 8-month in-segment MLD, late luminal loss, late loss index, and major adverse cardiac and cerebrovascular events. Procedural success was defined as the achievement of a residual in-stent stenosis of less than 30% associated with thrombolysis in myocardial infarction 3 flow, in the absence of a dissection of more than D1, a grade according to the National Heart, Lung, and Blood Institute classification, without the occurrence of death, myocardial infarction, or repeated target lesion revascularization during hospitalization. Major adverse cardiac and cerebrovascular events were defined as cardiac death, myocardial infarction (Q wave and non–Q wave), cerebrovascular accident, emergency or elective coronary artery bypass grafting, or emergency or elective repeated percutaneous transluminal coronary intervention of the target lesion. All deaths were considered cardiac unless an unequivocal noncardiac cause could be established. Q-wave myocardial infarction was defined as the occurrence of prolonged chest pain with an increase in the CK-MB fraction of more than 3 times the upper normal limit and the development of new abnormal Q waves: non–Q-wave myocardial infarction was defined as the absence of the latter. Target lesion revascularization was defined as repeated emergency or elective percutaneous transluminal coronary intervention or emergency or elective coronary artery bypass grafting performed because of restenosis of the target lesion in association with angina, objective evidence of myocardial ischemia, or both. A cerebrovascular accident was defined as the sudden onset of vertigo, numbness, aphasia, or dysarthria persisting for more than 24 hours.

Stent thrombosis was defined as an angiographic thrombus within the stented vessel at a clinically driven angiographic restudy for documented myocardial ischemia.

All major adverse cardiac and cerebrovascular events and stent thrombosis were determined for the in-hospital period, from hospital discharge up to 8 months, and cumulatively for all of the 8-month follow-up period; they were assessed by an independent clinical events committee unaware of treatment assignment.

Statistical Methods

On the basis of the available data concerning the restenosis rate in small arteries, it was calculated that the sample size required to demonstrate a 66% reduction in restenosis (from 30% to 10%) by means of a 2-sided test with an {alpha} error of .05 and a {beta} error of .10 was 103 patients per group. To compensate for unsuccessful interventions and losses to follow-up, the sample size was increased by 25% to 128 patients per group.

The continuous variables were compared between groups by using the t test. Categorical variables were compared using the {chi}2 test. The binary study end points were analyzed using the Fisher exact test; the relative risks or odds ratios and their 95% confidence intervals (CIs) are also reported. All of the statistical analyses were performed using SAS software (version 6.12; SAS Institute) on the basis of the intention-to-treat principle, ie, the primary analysis included all of the patients randomized to 1 of the 2 treatments and for whom follow-up coronary angiography was available, regardless of treatment actually received. Because of some imbalances in baseline characteristics, the main study results were confirmed by means of stratified analyses and by multivariable logistic regression analysis. Differences were considered statistically significant at P<.05 (2 tailed).


RESULTS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

The trial profile is shown in Figure 1.



View larger version (71K):
[in this window]
[in a new window]
Figure 1. Trial Profile


Between August 2002 and February 2003, 260 patients were enrolled in 20 Italian centers. Three patients were not randomized because of the discovery of exclusion criteria that became apparent only after enrollment. The final patient cohort therefore included 257 patients: 129 in the sirolimus-eluting stent group and 128 in the uncoated stent group.

Characteristics of the patients, lesions, and procedures are reported in Table 1 and Table 2. The groups were generally well matched in terms of patient and lesion characteristics; however, the patients treated with sirolimus-eluting stents had longer target lesions and therefore received longer stents. Procedural success rates were excellent (>95%) and similar in both groups. The patients in both groups had small vessels, with a mean reference diameter of only 2.2 (SD, 0.28) mm.


View this table:
[in this window]
[in a new window]
Table 1. Clinical and Angiographic Characteristics of the Patients



View this table:
[in this window]
[in a new window]
Table 2. Characteristics of the Procedures


Minimal luminal diameter and percentage of stenosis diameter at baseline and after stent implantation were similar in the 2 groups (Table 3). Follow-up angiographic data were available for 123 patients treated with sirolimus-eluting stents (95.3%) and 113 of those receiving uncoated stents (88.3%). After 8 months, the MLD, percentage of the stenosis diameter, late luminal loss, and the late loss index in the in-segment and in-stent zones improved more in the sirolimus-eluting stent group (P<.001 for all comparisons). The frequency of binary in-segment restenosis was 9.8% in the patients receiving sirolimus-eluting stents and 53.1% in those receiving uncoated stents (relative risk, 0.18; 95% CI, 0.10-0.32; P<.001); the frequency of binary in-stent restenosis was 4.9% and 49.1%, respectively (relative risk, 0.10; 95% CI, 0.04-0.22; P<.001). Cumulative frequency curves of in-segment percentage of the diameter of stenosis at baseline, after stent implantation, and at 8 months of follow-up are shown in Figure 2. In stratified analyses, the reduction of risk of restenosis with the sirolimus-eluting stent in comparison with the uncoated stent was independent of sex, diabetes mellitus status, clinical presentation (acute coronary syndrome vs chronic stable angina or silent myocardial ischemia), epicardial vessel location, stent diameter, and stent length (Figure 3). Similarly, in a multivariable logistic regression model, treatment with a sirolimus-eluting stent was associated with a markedly lower rate of restenosis (adjusted odds ratio, 0.11; 95% CI, 0.05-0.24; P<.001).


View this table:
[in this window]
[in a new window]
Table 3. Results of Quantitative Coronary Angiography




View larger version (25K):
[in this window]
[in a new window]
Figure 2. Cumulative Frequency of Stenosis

The cumulative frequency of the percentage of stenosis diameter at baseline, immediately after stent implantation, and after 8 months for patients receiving a sirolimus-eluting stent (solid lines) or an uncoated stent (dashed lines). Dotted line indicates threshold for restenosis.




View larger version (35K):
[in this window]
[in a new window]
Figure 3. Rates of Binary In-Segment Restenosis, Odds Ratios After 8 Months in the Patient Subgroups

CI indicates confidence interval; LAD, left anterior descending. The size of the data markers is proportional to the number of patients.
*Median unbiased exact odds ratio.


The major in-hospital, out-of-hospital, and cumulative 8-month adverse cardiac and cerebrovascular event rates are listed in Table 4. There were 2 deaths in the uncoated stent group (one caused by pneumonia and the other by stroke followed by pneumonia) and none in the sirolimus stent group. The cumulative frequency of myocardial infarction was lower in the sirolimus stent group (relative risk, 0.20; 95% CI, 0.01-0.93; P = .04). Target lesion revascularization was performed less frequently in the patients receiving sirolimus-eluting stents (relative risk, 0.33; 95% CI, 0.14-0.70; P = .002). Major adverse cardiac and cerebrovascular events were less frequently observed in the sirolimus stent group (relative risk, 0.30; 95% CI, 0.15-0.55; P<.001). Stent thrombosis was infrequent and occurred in 2 patients during hospital stay, 1 in the sirolimus stent group and 1 in the uncoated stent group; out-of-hospital stent thrombosis occurred in 3 of the patients receiving the uncoated stents and in none of the sirolimus stent group (relative risk, 0.26; 95% CI, 0.1-2.3). One of the non–Q-wave myocardial infarctions that occurred during hospitalization in the sirolimus stent group was clearly unrelated to the target lesion, as was the related stent thrombosis.


View this table:
[in this window]
[in a new window]
Table 4. Major Adverse Cardiac and Cerebrovascular Events in and Outside Hospital and Cumulatively During the 8 Months of Follow-up



COMMENT
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Percutaneous coronary revascularization by means of balloon angioplasty has a lower primary success rate and a higher restenosis rate in small coronary arteries than in large vessels.1-3 Restenosis in small coronary arteries may be as high as 50%, as an inverse relationship between vessel size and angiographic restenosis has reported.4-5 Stenting has become the major means of percutaneous coronary revascularization because it has been demonstrated to be superior to balloon angioplasty in preventing restenosis of new focal lesions in large coronary arteries,13-14 but conflicting results have been reported about efficacy in small vessels.15-20 Potential explanations for the lack of efficacy of coronary angioplasty with or without stent implantation in preventing restenosis in small vessels may be related to characteristics of patients harboring atherosclerotic small-vessel lesions, ie, women, diabetic patients, the elderly, and patients with peripheral vascular disease, all of whom are associated with a higher risk of restenosis.21-22 Another possible explanation may be related to the narrow diameter of the vessels, which cannot accommodate even minimal neointimal hyperplasia after angioplasty or stent deployment without becoming restenotic.

Given their ability to deliver prolonged and sufficient intramural drug concentrations to target coronary segments, drug-eluting stents are able to dramatically reduce neointimal hyperplasia,23-24 and this specific mechanism may be particularly useful in reducing restenosis in small coronary arteries.

The results of the present study demonstrate that the implantation of a sirolimus-eluting stent to treat atherosclerotic lesions of small coronary arteries is safe, effective, and associated with a lower incidence of angiographic restenosis in comparison with an uncoated stent. Because the 2 stents had an identical architecture, the only difference between them was the release of sirolimus, which reduced the rate of angiographic restenosis from 53.1% to 9.8%, with a relative risk reduction of 82%. The high restenosis rate observed in the uncoated stent group may partially account for the high absolute and relative risk reduction; however, this rate of restenosis is not all that surprising, given the high-risk population and high-risk lesions treated. Nevertheless, the 9.8% restenosis rate in the sirolimus-eluting stent group is also remarkably low. Previous post hoc analyses of the effect of overlapping sirolimus-eluting stents in small vessels revealed less satisfactory results (18.4% of restenosis in vessels with an average diameter of 2.32 mm).9 The use of adequately sized single stents that were almost 60% longer than the lesion may explain the remarkably low restenosis rate.

Not only was there a reduction in the risk of angiographic restenosis but also a lower rate of major adverse cardiovascular events, mainly because of the decreased incidence of ischemia-driven target-lesion revascularization and myocardial infarction. Why the implantation of a sirolimus-eluting stent may prevent the development of myocardial infarction remains unclear and needs to be confirmed. The beneficial effects of the sirolimus-eluting stent were achieved without any increase in complications, including stent thrombosis, which is a feared event, particularly in patients receiving stents in small vessels.

This was a single-blind, randomized trial, and therefore the cardiologists performing the procedure knew whether the patients were receiving a drug-eluting or an uncoated stent. However, the risk of a selection bias was minimized by the completely randomized design. Furthermore, because patients and the angiographic core laboratory personnel were blinded to the assigned treatment, symptom reporting and the angiographic results should not have been influenced by the open-label design.

Another possible limitation is related to the comparator bare-metal stent used. A different comparator with thinner struts might have led to a lower incidence of restenosis in the uncoated stent group. However, our purpose was to compare 2 angiographically indistinguishable stents with the same architecture to verify the effect of the eluting drug.

Despite these limitations, we found that in a highly challenging condition, namely, revascularization of small coronary arteries in patients with stable angina pectoris or acute coronary syndrome without ST-segment elevation, the use of sirolimus-eluting stents likely represents an advance in the prevention of angiographic restenosis and the short-term recurrence of adverse cardiac events. To establish their long-term efficacy and cost-effectiveness in the treatment of small coronary arteries, extended follow-up is required.


AUTHOR INFORMATION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Corresponding Author: Diego Ardissino, MD, Dipartimento del Cuore, Divisione di Cardiologia, Ospedale Maggiore di Parma, Università degli Studi di Parma, Via Gramsci 14, 43100 Parma, Italy (cardiologia.parma{at}ao.pr.it).

Author Contributions: Dr Ardissinio had full access to all of the data in the study and takes responsibility for the integrity of the data and the accuracy of the data analysis.

Study concept and design: Ardissino, Cavallini, Marzocchi, Merlini.

Acquisition of data: Ardissino, Bramucci, Indolfi, Marzocchi, Manari, Angeloni, Carosio, Repetto, Merlini.

Analysis and interpretation of data: Ardissino, Cavallini, Bonizzoni, Repetto, Merlini.

Drafting of the manuscript: Ardissino, Cavallini, Bonizzoni, Marzocchi, Colusso, Merlini.

Critical revision of the manuscript for important intellectual content: Ardissino, Bramucci, Indolfi, Manari, Angeloni, Carosio, Bonizzoni, Merlini.

Statistical analysis: Ardissino, Bonizzoni, Repetto, Merlini.

Obtained funding: Ardissino.

Administrative, technical, or material support: Ardissino, Merlini.

Study supervision: Ardissino.

Investigators and Institutions in the Sirolimus-Eluting Stent in the Prevention of Restenosis in Small Coronary Arteries (the SES-SMART Study)

Chairmen: Diego Ardissino, MD, Ospedale Maggiore di Parma, Universita’ degli Studi di Parma, Parma; Claudio Cavallini, MD, Ospedale Ca’ Foncello, Treviso.

Executive Committee: Ezio Bramucci, MD, Policlinico San Matteo, Universita’ degli Studi di Pavia, Pavia; Ciro Indolfi, MD, Universita’ degli Studi della Magna Grecia, Catanzaro; Antonio Marzocchi, MD, Policlinico Sant’Orsola, Universita’ degli Studi di Bologna, Bologna; Nello Becco, Cordis Italia, Milano.

Steering Committee: Antonio Manari, MD, Ospedale S. Maria Nuova, Reggio Emilia; Giulia Angeloni, MD, Università Cattolica Sacro Cuore di Roma, Policlinico A. Gemelli, Roma; Giuseppe Carosio, MD, Azienda Ospedaliera SS Antonio e Biagio e Cesare Arrigo, Alessandria; Enrico Aurier, MD, Ospedale Maggiore di Parma, Universita’ degli Studi di Parma, Parma; Luigi Piatti, MD, Ospedale A. Manzoni, Lecco; Roberto Violini, MD, Azienda Ospedaliera S. Camillo Forlanini, Roma; Pasquale Lisanti, MD, Azienda Ospedaliera S. Carlo, Potenza; Mauro De Benedictis, MD, Ospedale Mauriziano Umberto I, Torino; Giancarlo Piovaccari, MD, Ospedale Infermi, Rimini; Arturo Bande, MD, Azienda Ospedaliera G. Brotzu, Cagliari; Carmelo Cernigliaro, MD, Unità Operativa di Cardiologia Novara, Novara; Zoran Olivari, MD, Ospedale Cà Foncello, Treviso; Antonio Montinaro, MD, Azienda Unità Sanitaria Locale Lecce 1, Lecce; Roberto Bonmassari, MD, Ospedale S. Chiara, Trento; Enrico Magagnini, MD, Azienda Ospedaliera Universitaria Pisana Ospedale S. Chiara, Pisa; Giuseppe Steffenino, MD, Azienda Ospedaliera S. Croce e Carle, Cuneo; Stefano Tonioni, MD, Ospedale S. Pietro Fatebenefratelli, Roma.

Angiographic Core Laboratory: Maria Antonietta Bonardi, BSc, Monica Repetto, BSc, Mediolanum Cardio Research, Milano.

Statistical Analysis: Erminio Bonizzoni, BSc, Silvano Milani, BSc, University of Milan, Italy; Fabio Bravi, MD, Mediolanum Cardio Research, Milano.

Clinical Events Committee: Giuseppe Sangiorgi, MD, Ospedale Columbus, Milano; Flavio Airoldi, MD, Ospedale San Raffaele, Milano.

Principal Investigators or Study Coordinators: Roberta Rosso, MD, Policlinico San Matteo, Universita’ degli Studi di Pavia, Pavia (30 patients); Paola Giacometti, MD, Ospedale S. Maria Nuova, Reggio Emilia (28 patients); Paolo Ortolani, MD, Policlinico S. Orsola Malpighi, Bologna (26 patients); Rocco Mongiardo, MD, Università Cattolica Sacro Cuore di Roma, Policlinico A. Gemelli, Roma (20 patients); Giorgio Taverna, MD, Azienda Ospedaliera SS Antonio e Biagio e Cesare Arrigo, Alessandria (18 patients); Emilia Solinas, MD, Ospedale Maggiore di Parma, Universita’ degli Studi di Parma, Parma (16 patients); Mario Bossi, MD, Ospedale A. Manzoni, Lecco (14 patients); Francesco De Felice, MD, Azienda Ospedaliera S. Camillo Forlanini, Roma (14 patients); Gaetano Quaranta, MD, Azienda Ospedaliera S. Carlo, Potenza (12 patients); Mauro De Benedictis, MD, Ospedale Mauriziano Umberto I, Torino (11 patients); Andrea Santarelli, MD, Ospedale Infermi, Rimini (10 patients); Bruno Loi, MD, Azienda Ospedaliera G. Brotzu, Cagliari (9 patients); Angelo Sante Bongo, MD, Unità Operativa di Cardiologia Novara site 15, Novara (8 patients); Alessandro Daniotti, MD, Ospedale Cà Foncello, Treviso (8 patients); Giuseppe Colonna, MD, Azienda Unità Sanitaria Locale Lecce 1, Lecce (7 patients); Carmen Spaccorotella, MD, Policlinico Mater Domini, Catanzaro (6 patients); Massimiliano Marini, MD, Ospedale S. Chiara, Trento (5 patients); Andrea Pieroni, MD, Azienda Ospedaliera Universitaria Pisana Ospedale S. Chiara, Pisa (5 patients); Eugenio La Scala, MD, Azienda Ospedaliera S. Croce e Carle, Cuneo (5 patients); Roberto Serdoz, MD, Ospedale S. Pietro Fatebenefratelli, Roma (3 patients).

Funding/Support: This study was largely supported through institutional funds of the participating centers. There was complementary funding from Cordis Italia, Milan, Italy.

Role of the Sponsor: The sponsor provided free stents to the participating sites and was responsible for the logistics of the trial. The sponsor had no role in the study design, data analysis, and manuscript writing.

Independent Statistical Analysis: Drs Ardissino and Cavallini and the contract research organization (CRO) Mediolanum Cardiovascular Research had direct access to the raw data. The statistical analysis was performed by Erminio Bonizzoni, who is an academic statistician at the University of Milan. For this project he worked with Fabio Bravi (another independent statistician) as consultants for Mediolanum Cardiovascular Research. The statistical analyses were made independently of the sponsor, which had no access to the data. However, another academic statistician, Silavano Milani, not employed by the sponsor and without any relationship with the CRO, repeated the statistical analyses and provided written confirmation that the results are correct.

Acknowledgment: We thank Silvano Milani, Scuola di Specializzazione in Statistica Sanitaria, University of Milan, who performed an independent statistical analysis and confirmed our results.

Author Affiliations: Division of Cardiology, Ospedale Maggiore, University of Parma (Dr Ardissino); Division of Cardiology, Ospedale Ca’ Foncello, Treviso (Dr Cavallini); Division of Cardiology, Policlinico San Matteo, Istituto di Ricovero e Cura a Carattere Scientifico, University of Pavia (Dr Bramucci); Division of Cardiology, University of Magna Grecia, Catanzaro (Dr Indolfi); Division of Cardiology, Ospedale Sant’Orsola, University of Bologna (Dr Marzocchi); Division of Cardiology, Ospedale Santa Maria Nuova, Reggio Emilia (Dr Manari); Division of Cardiology, Policlinico A. Gemelli, University of Sacro Cuore, Rome (Dr Angeloni); Division of Cardiology, Ospedale SS Antonio e Biagio e Cesare Arrigo, Alessandria (Dr Carosio); Mediolanum Cardio Research (Mss Colusso and Repetto); Institute of Medical Statistics and Biometry, University of Milan (Dr Bonizzoni); and Division of Cardiology, Ospedale Niguarda, Milan (Dr Merlini), Italy.


REFERENCES
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

1. Foley DP, Melkert R, Serruys PW, and the CARPORT, MERCATOR, MARCATOR, and PARK Investigators. Influence of vessel size on renarrowing process and late angiographic outcome after successful balloon angioplasty. Circulation. 1994;90:1239-1251. FREE FULL TEXT
2. Schunkert H, Harrel L, Palacios IF. Implications of small reference vessel diameter in patients undergoing percutaneous coronary revascularization. J Am Coll Cardiol. 1999;34:40-48. FREE FULL TEXT
3. Hirshfeld JW, Schwartz JS, Jugo R, et al, and the M-HEART Investigators. Restenosis after coronary angioplasty: a multivariate statistical model to relate lesion and procedure variables to restenosis. J Am Coll Cardiol. 1991;18:647-656. ABSTRACT
4. Elezi S, Kastrati A, Neumann FJ, et al. Vessel size and long-term outcome after coronary stent placement. Circulation. 1998;98:1875-1880. FREE FULL TEXT
5. Akiyama T, Moussa I, Reimers B, et al. Angiographic and clinical outcome following coronary stenting of small vessels: a comparison with coronary stenting in large vessels. J Am Coll Cardiol. 1998;32:1610-1618. FREE FULL TEXT
6. Crosby IK, Wellons HAJ, Taylor GJ, Maffeo CJ, Beller GA, Muller WH. Critical analysis of the preoperative and operative predictors of aortocoronary bypass patency. Ann Surg. 1981;193:743-751. ISI | PUBMED
7. O’Connor NJ, Morton JR, Birkmeyer JD, Olmstead EM, O’Connor JT, Northern New England Cardiovascular Disease Study Group. Effect of coronary artery diameter in patients undergoing coronary by-pass surgery. Circulation. 1996;93:652-655. FREE FULL TEXT
8. Morice MC, Serruys PW, Sousa JE, et al, RAVEL Study Group. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002;346:1773-1780. FREE FULL TEXT
9. Moses JW, Leon MB, Popma JJ, et al, SIRIUS Investigators. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003;349:1315-1323. FREE FULL TEXT
10. Schofer J, Schluter M, Gershlick AH, et al, for the E-SIRIUS Investigators. Sirolimus eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS). Lancet. 2003;362:1093-1099. FULL TEXT | ISI | PUBMED
11. Stone GW, Ellis SG, Cox DA, et al, for the TAXUS IV Investigators. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med. 2004;350:221-231. FREE FULL TEXT
12. Ardissino D, Barberis P, De Servi S, et al. Abnormal coronary vasoconstriction as a predictor of restenosis after successful coronary angioplasty in patients with unstable angina pectoris. N Engl J Med. 1991;325:1053-1057. ABSTRACT
13. Serruys PW, de Jaegere P, Kiemeneij F, et al, Benestent Study Group. A comparison of balloon-expandable implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med. 1994;331:489-495. FREE FULL TEXT
14. Fischman DL, Leon MB, Baim DS, et al. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med. 1994;331:496-501. FREE FULL TEXT
15. Savage MP, Fishman DL, Rake R, et al, Stent Restenosis Study (STRESS) Investigators. Efficacy of coronary stenting versus balloon angioplasty in small coronary arteries. J Am Coll Cardiol. 1998;31:307-311. FREE FULL TEXT
16. Kastrati A, Schoming A, Dirshinger J, et al, ISAR-SMART Study Investigators. A randomized trial comparing stenting with balloon angioplasty in small vessels in patients with symptomatic coronary artery disease: Intracoronary Stenting or Angioplasty for Restenosis Reduction in Small Arteries. Circulation. 2000;102:2593-2598. FREE FULL TEXT
17. Moer R, Myreng Y, Molstad P, et al. Stenting in small coronary arteries (SISCA trial). J Am Coll Cardiol. 2001;38:1598-1603. FREE FULL TEXT
18. Doucet S, Schalij MJ, Vrolix MCM, et al. Stent placement to prevent restenosis after angioplasty in small coronary arteries. Circulation. 2001;104:2029-2033. FREE FULL TEXT
19. Koning R, Eltchaninoff H, Commeau P, et al, BESMART Group. Stents placement compared with balloon angioplasty for small coronary arteries: in-hospital and 6-month clinical and angiographic results. Circulation. 2001;104:1604-1608. FREE FULL TEXT
20. Briguori C, Nishida T, Adamian M, et al. Coronary stenting versus balloon angioplasty in small coronary artery with complex lesions. Catheter Cardiovasc Interv. 2000;50:390-397. FULL TEXT | ISI | PUBMED
21. Mehilli J, Kastrati A, Dirschinger J, Bollwein H, Neumann FJ, Schomig A. Differences in prognostic factors and outcomes between women and men undergoing coronary artery stenting. JAMA. 2000;284:1799-1805. FREE FULL TEXT
22. Al Suwaidi J, Berger PB, Holmes DR. Coronary artery stents. JAMA. 2000;284:1828-1836. FREE FULL TEXT
23. Heitman J, Movva NR, Hall MN. Target for cell cycle arrest by the immunosuppressant rapamycine in yeast. Science. 1991;253:905-909. FREE FULL TEXT
24. Sousa JE, Costa MA, Abizaid AC, et al. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-dimensional intravascular ultrasound study. Circulation. 2001;103:192-195. FREE FULL TEXT

RELATED ARTICLE

Stenting Small Coronary Arteries: Works in Progress
David R. Holmes, Jr
JAMA. 2004;292(22):2777-2778.
EXTRACT | FULL TEXT  


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Long-term benefit-risk balance of drug-eluting vs. bare-metal stents in daily practice: does stent diameter matter? Three-year follow-up of BASKET
Pfisterer et al.
Eur Heart J 2008;0:ehn516v1-9.
ABSTRACT | FULL TEXT  

Effects of aspirin dose on ischaemic events and bleeding after percutaneous coronary intervention: insights from the PCI-CURE study
Jolly et al.
Eur Heart J 2008;0:ehn417v1-8.
ABSTRACT | FULL TEXT  

Outcomes and Complications With Off-Label Use of Drug-Eluting Stents: Results From the STENT (Strategic Transcatheter Evaluation of New Therapies) Group
Brodie et al.
J Am Coll Cardiol Intv 2008;1:405-414.
ABSTRACT | FULL TEXT  

Drug-Eluting Stents: Life Insurance With a Better Death Benefit
Anderson
J Am Coll Cardiol 2008;51:2025-2027.
FULL TEXT  

Comparison of Coronary Artery Stenting Outcomes in the Eras Before and After the Introduction of Drug-Eluting Stents
Hannan et al.
Circulation 2008;117:2071-2078.
ABSTRACT | FULL TEXT  

Current Status of Off-pump Coronary Artery Bypass Surgery
Raja and Dreyfus
Asian Cardiovasc. Thorac. Ann. 2008;16:164-178.
ABSTRACT | FULL TEXT  

Drug-Eluting Versus Bare-Metal Stents in the Treatment of Patients With ST-Segment Elevation Myocardial Infarction
Hannan et al.
J Am Coll Cardiol Intv 2008;1:129-135.
ABSTRACT | FULL TEXT  

Overview of the 2007 Food and Drug Administration Circulatory System Devices Panel Meeting on the Endeavor Zotarolimus-Eluting Coronary Stent
Pinto Slottow and Waksman
Circulation 2008;117:1603-1608.
FULL TEXT  

The Problem With Composite End Points in Cardiovascular Studies The Story of Major Adverse Cardiac Events and Percutaneous Coronary Intervention.
Kip et al.
J Am Coll Cardiol 2008;51:701-707.
ABSTRACT | FULL TEXT  

Two-Year Clinical Outcomes With Drug-Eluting Stents for Diabetic Patients With De Novo Coronary Lesions: Results From a Real-World Multicenter Registry
Ortolani et al.
Circulation 2008;117:923-930.
ABSTRACT | FULL TEXT  

Drug-eluting stents: do the risks really outweigh the benefits?
Austin et al.
Heart 2008;94:127-128.
FULL TEXT  

Effectiveness of Drug-Eluting Stents in Real-World Patients
Mukherjee and Moliterno
JAMA 2008;299:454-455.
FULL TEXT  

Drug-Eluting Stents vs. Coronary-Artery Bypass Grafting in Multivessel Coronary Disease
Hannan et al.
NEJM 2008;358:331-341.
ABSTRACT | FULL TEXT  

Acute Thrombosis of a Mesenteric Artery Drug-Eluting Stent Following Clopidogrel Cessation
Sutphin et al.
VASC ENDOVASCULAR SURG 2008;41:564-567.
ABSTRACT  

Myocardial Revascularization with Percutaneous Devices
Wilson and Willerson
Card Surg Adult 2008;3:573-598.
FULL TEXT  

Impact of Vessel Size on Outcome After Implantation of Sirolimus-Eluting and Paclitaxel-