You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT JAMA
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 264 No. 19, November 21, 1990 TABLE OF CONTENTS
  JAMA
  •  Online Features
  Letters
 This Article
 •References
 •Full text PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citing articles on HighWire
 •Contact me when this article is cited
 Related Content
 •Similar articles in JAMA
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Determination of HIV-1 Status of Discarded Sharps: Polymerase Chain Reaction Using Minute Quantities of Blood

Stephen Raffanti, MD; Anders Svenningsson, MD; Lionel Resnick, MD
Mount Sinai Medical Center Miami, Fla

JAMA. 1990;264(19):2501.

Since this article does not have an abstract, we have provided the first 150 words of the full text PDF and any section headings.

To the Editor.—

As the number of individuals infected with human immunodeficiency virus type 1 (HIV-1) grows, the potential for accidental needle-stick injuries with contaminated blood increases. Strict adherence to infectioncontrol guidelines may limit this hazard. However, needle-stick injuries by discarded sharps present a special problem if the patient source of the needle is unknown.

Report of a Case.—

A nurse in an outpatient medical office had an accidental needle-stick exposure with a discarded angiocatheter. Many catheterization procedures had been performed, and the patient source was unknown. On the day of the accident, the angiocatheter was submitted to our laboratory and approximately 60 µL of serum was aspirated from the clotted blood in the hub of the needle. The sample was reactive to HIV-1 by Western immunoblot.1 The needle was flushed with 300 µL of phosphate-buffered saline, and the eluant was processed for DNA extraction and polymerase . . . [Full Text PDF of this Article]


Footnotes

Edited by Drummond Rennie, MD, Deputy Editor (West), and Don Riesenberg, MD, Senior Editor.